using System.Text.Json; using AutoForge.Application.Features.DisplayUnits; using AutoForge.Diagnostics; namespace AutoForge.UI.Features.DisplayUnits; public sealed record DisplayUnitText(string Value, string Unit, string? Notice = null, string? Error = null); public static class DisplayUnitPresentation { public static string FormatSourceValue(JsonElement sourceValue) => sourceValue.ValueKind switch { JsonValueKind.Undefined => "undefined", JsonValueKind.Null => "null", JsonValueKind.String => sourceValue.GetString() ?? string.Empty, _ => sourceValue.GetRawText() }; public static DisplayUnitText Project( JsonElement sourceValue, string sourceUnit, DisplayUnitSelection selection, int precision = 3) { return Project(sourceValue, sourceUnit, selection, SignalQuality.Good, precision); } public static DisplayUnitText Project( JsonElement sourceValue, string sourceUnit, DisplayUnitSelection selection, SignalQuality quality, int precision = 3) { if (quality == SignalQuality.Unknown) { return new DisplayUnitText("--", sourceUnit, Notice: "The source quality is Unknown; the current measurement is unavailable."); } if (!Enum.IsDefined(quality)) { return new DisplayUnitText("--", sourceUnit, Error: "The source quality is undefined."); } if (sourceValue.ValueKind is JsonValueKind.Null or JsonValueKind.Undefined) { return new DisplayUnitText("--", sourceUnit, Error: "The source measurement is missing or null."); } if (sourceUnit == "boolean") { if (sourceValue.ValueKind is JsonValueKind.True or JsonValueKind.False) { return new DisplayUnitText(sourceValue.GetRawText(), sourceUnit, GetQualityNotice(quality)); } return new DisplayUnitText("--", sourceUnit, Error: "The boolean source value has the wrong JSON type."); } if (!DisplayUnitConverter.IsKnownNumericUnit(sourceUnit)) { return new DisplayUnitText( FormatSourceValue(sourceValue), sourceUnit, CombineNotices( $"Unit '{sourceUnit}' is not in the supported display mapping; showing the exact source value and unit.", GetQualityNotice(quality))); } if (sourceValue.ValueKind != JsonValueKind.Number || !sourceValue.TryGetDouble(out var number) || !double.IsFinite(number)) { return new DisplayUnitText("--", sourceUnit, Error: "The numeric source value is missing, non-numeric or non-finite."); } return ProjectNumber(number, sourceUnit, selection, quality, precision); } public static DisplayUnitText Project( double? sourceValue, string sourceText, string sourceUnit, DisplayUnitSelection selection, int precision = 3) => Project(sourceValue, sourceText, sourceUnit, selection, SignalQuality.Good, precision); public static DisplayUnitText Project( double? sourceValue, string sourceText, string sourceUnit, DisplayUnitSelection selection, SignalQuality quality, int precision = 3) { if (quality == SignalQuality.Unknown) { return new DisplayUnitText("--", sourceUnit, Notice: "The source quality is Unknown; the current measurement is unavailable."); } if (!Enum.IsDefined(quality)) { return new DisplayUnitText("--", sourceUnit, Error: "The source quality is undefined."); } if (sourceUnit == "boolean") { if (sourceValue is null && bool.TryParse(sourceText, out var boolean)) { return new DisplayUnitText(boolean ? "true" : "false", sourceUnit, GetQualityNotice(quality)); } return new DisplayUnitText("--", sourceUnit, Error: "The boolean source value is missing or has the wrong type."); } if (sourceValue is not { } numericValue) { if (string.IsNullOrEmpty(sourceText) || StringComparer.OrdinalIgnoreCase.Equals(sourceText, "null")) { return new DisplayUnitText("--", sourceUnit, Error: "The source measurement is missing or null."); } return DisplayUnitConverter.IsKnownNumericUnit(sourceUnit) ? new DisplayUnitText("--", sourceUnit, Error: "The numeric source value is missing, non-numeric or non-finite.") : new DisplayUnitText( sourceText, sourceUnit, CombineNotices( $"Unit '{sourceUnit}' is not in the supported display mapping; showing the exact source value and unit.", GetQualityNotice(quality))); } if (!double.IsFinite(numericValue)) { return new DisplayUnitText("--", sourceUnit, Error: "The numeric source value is non-finite."); } if (!DisplayUnitConverter.IsKnownNumericUnit(sourceUnit)) { return new DisplayUnitText( sourceText, sourceUnit, CombineNotices( $"Unit '{sourceUnit}' is not in the supported display mapping; showing the exact source value and unit.", GetQualityNotice(quality))); } return ProjectNumber(numericValue, sourceUnit, selection, quality, precision); } private static DisplayUnitText ProjectNumber( double value, string sourceUnit, DisplayUnitSelection selection, SignalQuality quality, int precision) { var measurement = DisplayUnitConverter.Project(value, sourceUnit, selection); return new DisplayUnitText( DisplayUnitConverter.Format(measurement, precision), measurement.Unit, CombineNotices(measurement.Notice, GetQualityNotice(quality)), measurement.Error); } private static string? GetQualityNotice(SignalQuality quality) => quality == SignalQuality.Uncertain ? "The source marked this finite value Uncertain." : null; private static string? CombineNotices(string? first, string? second) => first is null ? second : second is null ? first : $"{first} {second}"; }