# Build and test ## Prerequisites - Windows x64, .NET SDK 10.0.402 with its approved .NET 10 patch roll-forward. - Windows SDK target 10.0.26100.0 and MAUI Windows workload manifest 10.0.110. - Microsoft Edge WebView2 Runtime to launch the native Blazor Hybrid Client. The previously verified environment reported runtime 10.0.13, MAUI workload version 10.0.403 as listed by the installed SDK, and WebView2 Runtime 155.0.4283.62. The Client targets `net10.0-windows10.0.26100.0` and `win-x64`. All other projects target portable `net10.0`; tests do not require MAUI or WebView2. ## Restore, build, test and launch From the repository root in PowerShell, run the full build and both suites sequentially: ```powershell dotnet restore .\src\AutoForge.slnx dotnet build .\src\AutoForge.slnx --configuration Release --no-restore dotnet test .\src\AutoForge.slnx --configuration Release --no-build dotnet run --project .\src\AutoForge.Client\AutoForge.Client.csproj --configuration Release --framework net10.0-windows10.0.26100.0 ``` The build includes the actual native Client and all nine solution projects. For an explicit Windows runtime pack restore or direct native build: ```powershell dotnet restore .\src\AutoForge.Client\AutoForge.Client.csproj --runtime win-x64 dotnet build .\src\AutoForge.Client\AutoForge.Client.csproj --configuration Release --framework net10.0-windows10.0.26100.0 --no-restore ``` Do not pass Windows TFM overrides to the portable test projects. The Client contains the real UI RCL in a native MAUI BlazorWebView. No automotive driver, actual vehicle, database, backend, model or cloud account is required. ## Focused tests ```powershell dotnet test .\src\tests\AutoForge.UnitTests\AutoForge.UnitTests.csproj --configuration Release dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~TelemetryReplayTests|FullyQualifiedName~LiveDashboardAcquisitionTests|FullyQualifiedName~DisplayUnitControlTests" dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~CalibrationAuthoringTests" dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~CalibrationRehearsalTests|FullyQualifiedName~RenderedRehearsal|FullyQualifiedName~RehearsalIsolation|FullyQualifiedName~CalibrationAuthoringTests" ``` ## Step-10 simulated programming rehearsal verification Step-09 is accepted; Step-10 remains pending manual review. The final focused command passed **86 cases**: 31 new rehearsal cases plus 55 accepted authoring cases. They use actual Simulation target storage/CAS through typed Diagnostics ports, real authoring/configuration/profile services and controlled forwarding faults. Independent backup, complete scalar/table readback, immutable approval, stale head/target CAS, cancellation before/after actual commit, exact repeated operations, negative/echoed/lost acknowledgements, divergent/missing reads, read-only reconciliation, separately approved Restore, held close/failure drainage and exact 32/33 audit capacity are verified. The required sequential Release build completed all nine projects/native Client with zero warnings/errors. The full suite passed **179 unit + 257 integration = 436 cases**, zero failed/skipped, preserving all 405 baseline cases. Real live dynamics/diagnostics, saved recording and validated replay coexist while rehearsal adds zero calls to their transport/model/archive Save boundaries and leaves configuration export, live trace/status, archive bytes, authoring history and replay snapshot unchanged. Native smoke used the actual rebuilt Windows Client and task-owned WebView2 profile/local DevTools port. Within `/calibration`, an explicitly created warm configuration/proposal opened the distinct Simulation rehearsal target. Two independent reads produced its verified supported-image backup at revision 0. Explicit scalar Apply yielded 1250 rpm with all torque cells unchanged at revision 1. A new proposal changed only 2000-rpm torque 360->350 N*m; its new approval/full readback yielded revision 2. Separately confirmed original Restore yielded 650 rpm and every original torque cell/axis at revision 3. Close left inactive evidence; reopen created a different instance with no old backup/ approval/audit. Restore without a fresh backup rejected. The native source export/fingerprint remained identical, with source warm idle 650 rpm and 2000-rpm torque 360 N*m. A separate actual dynamics read at model step 7 returned 631.80416 rpm, not the rehearsal's 1250 image. Display units preserved an unconsumed approval without dispatch; exact repeat dispatched no second mutation. Original Metric/Road preferences and old replay/home routes worked. Initial fast automation hit stale-head/DOM-readiness rejections; exact selected/current-head feedback and settled real controls were then used for the complete successful workflow. Those are not controlled race/fault proofs. See the [Step-10 worker report](../prompts/Step-10-Report.md) for exact normal/ controlled evidence, commands, cleanup and preservation. ## Step-09 synthetic authoring verification Steps 08 and 09 are accepted. The historical Step-09 worker evidence follows. The focused authoring command above passed **55 cases**, including real configuration/profile source resolution, exact 650->1250 rpm and 360->350 N*m diffs/parents, changed-back/no-op/tiny changes, defensive copies, template/source rejection, controlled competing-head commits and the exact 32/33 history boundary. Real rendered events verify parse/validation failures, history/diff selection, two stale editors, explicit replacement and pinned torque units with exact canonical preservation. The required sequential Release build completed all nine projects/native Client with zero warnings/errors, then the complete suite passed **179 unit + 226 integration = 405 cases**, zero failed/skipped. All 350 accepted baseline cases remain present. A real live dynamics source, its saved recording and validated replay coexist during authoring with zero additional transport, model-control and archive Save calls, unchanged source export/fingerprint/ trace/state/raw bytes and unchanged replay snapshot. Native smoke used the actual Release Windows Client and a task-owned WebView2 profile/local DevTools endpoint. The existing simulation workflow explicitly created the warm source. Native authoring created its baseline, saved the 1250-rpm scalar proposal and 350-N*m torque cell at 2000 rpm, then inspected exact baseline and preceding-version diffs. Invalid scalar/cell/source commands and unconfirmed replacement preserved the head/history. A Metric draft's unsaved 345 N*m remained 345 after an Imperial toggle; cancelling captured a new Imperial draft, and an untouched save across another toggle retained exact source 350 N*m and the same revision. Confirmed replacement explicitly discarded the old draft/history and returned to baseline. The original dynamics configuration export/fingerprint stayed identical with warm idle 650 rpm and 2000-rpm torque 360 N*m. An explicit subsequent real diagnostic read at model step 7 / 0.7 seconds returned 631.80416 rpm from the unchanged warm model, not the proposal. Old simulation/profile/replay routes and authoring re-entry worked. Restart confirmed no authoring workspace or configuration persisted; the final binary then repeated the baseline and two-proposal diff workflow. Native observations are not controlled concurrent/ stale-head/capacity proof. Exact commands, final results, cleanup and limitations are in the [Step-09 worker report](../prompts/Step-09-Report.md). ## Step-08 recorded replay verification Corrected Step-07/07A/07B and Step-08 are accepted. The recorded Step-08 focused command passed 49 cases. It covers 37 new replay cases plus accepted live-dashboard/unit-selector regressions. The required sequential nine-project Release build passed with zero warnings and errors, followed by 179 unit and 171 integration tests: **350 passed, zero failed/skipped**, preserving all 313 baseline cases. The replay tests construct real recorder/codec/file-store inputs, then dispose their original sources and load without profile/configuration catalogues. Independent four-observation assertions cover exact prefixes, last-Good versus Uncertain, ties, before-first, zero/empty/non-signal archives and model reset/ repeated time. Controlled monotonic waits/barriers prove 0.25x/1x/1000x pacing, 1.5-to-1.7-second mid-gap pause at 2x, remaining 0.15-second resume, held cleanup, fault recovery (including faults during pending Pause/Stop cleanup), stale loads/wakes and unmount. Actual rendered route/editor events prove committed selector feedback, persistent actual fault reasons despite older command errors, partial acknowledgement, pinned units and atomic edits. A real simultaneously open dynamics source retains its trace, model state and unsaved recording with zero additional transport, model-control or archive Save calls during replay. Shared gauge hide/units/ unmount also leaves an active replay owner untouched. Native smoke uses the actual Windows Client through a task-local WebView2 DevTools endpoint, not a second web host. Saved static-v1 and dynamic-v2 captures were recorded through native controls, stopped, source-closed and saved. After app restart, the profile catalogue was empty; both files replayed without reimporting profiles or recreating a model/configuration. Native checks include explicit load/no autoplay, numeric/bar gauges, Play/Pause/Stop/First/Restart, time/ordinal/backward navigation, rejected speed feedback, hide/show, end, route close/re-entry, raw/decoded inspection and restored Metric/Road preferences. A recorded 88.02090573589594 degC source showed 88.02 degC or 190.44 degF; draft 32..212 degF saved without changing canonical 0..100 degC bounds. Time seek 40,000,000 ticks retained exactly two of four dynamic records. The native partial warning/acknowledgement/end check used a separately named, strict-reader-validated derived static fixture; it is not evidence that native recording exhausted a limit. Actual limit/error capture and controlled timing/ fault/interleaving evidence remain in headless tests. Static/dynamic archive SHA-256 hashes were unchanged after playback. Exact task-owned capture IDs, storage path, cleanup and native preparation limitations are recorded in the [Step-08 worker report](../prompts/Step-08-Report.md). MAUI storage was verified at its real app-local directory, not inferred from `LOCALAPPDATA`. Only individually named task-owned capture files and task-owned WebView profile/helper were cleaned up; unrelated app data/preferences remain. The unit suite covers existing Core/Application behavior, rendered generic components, profile invariants and strict codec behavior, plus protocol v1 round-trip/snapshot contracts and bounded trace behavior. The integration suite loads source-controlled profile fixtures through real DI, opens actual simulation sessions, sends/decodes requests through the transport, verifies identity/DTC/static signals, virtual clear/readback/reset and independent session state, exercises deterministic malformed/no-response/timeout/cancelled faults, renders the diagnostic route against the actual provider, and checks the nine-project reference graph. Fixtures are never treated as real vehicle definitions. The internal state oracle is exposed only to the integration-test assembly. The accepted Step-02A baseline was 103 unit plus 37 integration tests (140 total). The Step-03 worker report records the full, expanded counts, warnings, commands and native observations; do not infer acceptance from these earlier runs. Historical Step-02 had 59 unit and 34 integration cases; it predates the Step-02A corrections. See the [Step-02 report](../prompts/Step-02-Report.md) and [Step-02A report](../prompts/Step-02A-Report.md) for historical evidence. Step-03 worker verification ran the nine-project Release build with zero warnings/errors, then passed 108 unit and 53 integration cases (161 total, zero failed/skipped). Its native smoke used the actual Windows Client and verified explicit synthetic selection, module probes/identity, DTC and static signals, raw request/reply trace, virtual clear/readback/reset, close, target metadata, profile, home and not-found routes. Exact observations and limitations are recorded in the [Step-03 worker report](../prompts/Step-03-Report.md); the run did not cover the subsequently identified integrity findings and Step-03 was not accepted. Step-03A added actual failing-before/passing-after regressions for missing and duplicate request fields, semantic response validation/trace consistency, and clear acknowledgement versus verified readback. The final sequential Release verification passed 111 unit tests and 64 integration tests (175 total, zero failed/skipped), preserving the original 161 cases plus 14 additional test cases. Exact commands and outcome details are in the [Step-03A corrective report](../prompts/Step-03A-Report.md). Manual orchestrator acceptance remains pending. Step-03B reproduced the probe-only identity-loss defect before the fix through the real Simulation transport: the regression expected a positive probe but observed a negative discovery outcome. After the correction, the focused protocol/UI integration selection passed 35 cases. The complete nine-project Release build passed with zero warnings and errors, and the complete suite passed 111 unit plus 72 integration tests (183 total, zero failed/skipped), preserving all 175 Step-03A cases. Exact commands and AC mapping are recorded in the [Step-03B corrective report](../prompts/Step-03B-Report.md). The native Windows Client was launched and the operational baseline was exercised in its own WebView: explicit example import/profile/revision/provider/ Simulation selection, session open, discovery with expected/probe/identity counts, configured transmission no-response, engine DTC/static-signal reads, verified clear with fresh empty readback, raw/decoded trace, reset with initial DTC restoration, close, and `/execution-targets`, `/vehicle-profiles`, `/`, and not-found routes. Exact observations and limitations are in the [Step-03B corrective report](../prompts/Step-03B-Report.md). Native interaction used a session-local WebView debug port on the worker-launched Client; partial identity remains covered by real-DI rendered tests because the shipped native configuration has no fault selector for that scenario. ## Step-04 fixed-step dynamics verification The Step-04 Release regression ran sequentially against the full solution: ```powershell dotnet build .\src\AutoForge.slnx --configuration Release --no-restore dotnet test .\src\AutoForge.slnx --configuration Release --no-build ``` The native Windows-targeted build covered all nine solution projects with zero warnings/errors. The complete test command passed 115 unit and 75 integration tests (190 total, zero failed/skipped), preserving the Step-03B 183-test baseline. The unit numerical gate executes 3,361 deterministic 0.1-second samples and compares full sampled state across equal runs. The baseline results were: 10.0 s warm idle at 650.000 rpm; acceleration to 20.1473 m/s in 10.3 s with four scheduled shifts; all 3,000 cruise samples inside the configured 45-MPH +/- 1-MPH band and fully coupled; braking to 0.0000 m/s in 5.8 s; 10.0 s return idle; and 0.518387 kg modeled total fuel. These are synthetic model outputs, not measured vehicle performance or manufacturer predictions. The actual Windows Client was launched with WebView2 local DevTools enabled for the native smoke. `/simulation` required explicit selection of profile `autoforge.synthetic.test-truck` revision 1, provider `autoforge.simulation.dynamics`, and a configuration with fingerprint `sha256:v1:e8991ae139b54959ec53a4fe64b08dc9bfc03feb533496cf741f2c9f3a2342da`. Export/import preserved that fingerprint. A stopped open session returned 17 protocol-v2 dynamic telemetry values at step 4 / 0.4 model seconds after explicit start/pause/step controls. The accelerated full scenario completed at step 3,361 / 336.1 model seconds with 17 telemetry values and four shifts. Invalid `{}` import visibly reported the missing required `formatVersion`; exact-config reset opened a new session at step 0 with the same fingerprint, and close released it. The native `/diagnostics` regression separately selected the original `autoforge.simulation.synthetic` provider, discovered two positive probes out of three expected endpoints (the transmission remained configured no-response), and read the original engine DTC plus static 850-rpm and 12.6-V signals through protocol v1 with trace records. The session was closed. Native route smoke covered `/execution-targets` (both providers remain metadata), `/vehicle-profiles`, `/`, and an unmatched not-found route. Numerical fidelity and reproducibility are established by headless tests, not by visual telemetry. ## Native synthetic diagnostics smoke Launch the actual Windows Client and visit `/diagnostics`: 1. Confirm the page starts without selecting/importing a profile or opening a session. Click **Load synthetic truck example**; verify the profile appears as an available revision but remains unselected. 2. Explicitly select `autoforge.synthetic.test-truck`, revision `1`, provider `autoforge.simulation.synthetic`, and kind `Simulation`. Click **Open simulation session** and confirm the visible session/profile/provider/ configuration identity. The session opens in process only. 3. Click **Probe virtual modules**. Engine/body respond; the configured transmission endpoint visibly reports no response and is not reported as an actual responder. Inspect the identity and declared implemented services. 4. Read the engine's DTCs and static signals. Values are synthetic static snapshots with source, unit, quality and logical tick. Expand the bounded trace to inspect actual request/response JSON and correlation values. 5. Clear the supported engine virtual DTCs, confirm the fresh readback is empty, and confirm the UI explicitly states that no physical write occurred. Other module/session state is isolated. 6. Exercise a visible deterministic failure (for example the configured transmission no-response), then reset to the initial synthetic state and close the session. Closing releases that session's trace and virtual state. 7. Separately visit `/execution-targets`, `/vehicle-profiles`, `/`, and an unmatched route. Confirm metadata selection remains separate from an operational session and the not-found/navigation behavior remains. The Step-03A report records actual native baseline smoke separately from headless rendered fault tests. The native Client revalidated explicit profile/provider selection, successful clear with fresh empty readback, trace/raw frames, visible no-response, reset/initial-state restoration, close and existing routes. A deliberately false clear acknowledgement was injected only in the rendered integration composition; the production Client has no UI fault selector, so this is not native fault-injection evidence. ## Profile-schema and safety boundaries See the [schema-v1 guide](vehicle-profile-schema-v1.md) for field, identity, unknown-value, capability, provenance and strict JSON rules. Important invariants: - Every v1 field is required; unknown optional facts are explicit JSON `null`. Unknown fields and duplicate/case-ambiguous properties are rejected. - Catalog selection requires exact `(profileIdentifier, revision)`. Duplicate imports do not replace entries, and failed parsing cannot partially register. - `publishedAt`/`retrievedAt` accept null or complete `YYYY-MM-DDTHH:mm:ss[.fraction](Z|+HH:mm|-HH:mm)` timestamps only. The exact fractional and offset limits and no-default policy are in the schema guide. - A null optional module identity in evidence is an absent constraint. Any supplied identity must match a known module value; an unknown target or mismatch is rejected without identity inference. - Imported profiles and capability/provenance statements are immutable metadata, not connection, compatibility, a working service or authorization. - Data remains in memory for the process only. JSON import/export does not write files or timestamps implicitly. - Static synthetic diagnostics use the [protocol v1 guide](synthetic-diagnostics-v1.md) and [simulation definitions](simulation.md); dynamic output uses the separate documented protocol-v2 provider. Neither is a real vehicle adapter, telemetry capture, replay provider, calibration/firmware editor or hardware write path. ## Step-04A corrective verification Step-04A corrects typed import errors for unavailable profile/revision/module or conflicting calibration references, enforces the supported coupled RPM/redline envelope, and makes progress, terminal failure and asynchronous runner ownership explicit. It adds seven unit and five integration cases over the 190-case Step-04 baseline. The final sequential commands were: `dotnet build .\src\AutoForge.slnx --configuration Release --no-restore` `dotnet test .\src\AutoForge.slnx --configuration Release --no-build` The nine-project Windows Release build succeeded with zero warnings and zero errors. The full test command passed 122 unit and 80 integration tests (202 total; zero failed/skipped). The warm baseline remains reproducible at 3,361 samples / 336.1 virtual seconds; 10.0 s warm idle at 650 rpm, 10.3 s acceleration to 20.1473 m/s with four shifts, all 3,000 cruise samples in the original 45-MPH +/- 1-MPH band while coupled, braking to 0.0000 m/s in 5.8 s, 10.0 s return idle, and 0.518387 kg modeled fuel. The added independent constant-torque force/mass equation and speed-step equation checks use a `1e-10` acceleration tolerance; independent locked RPM checks use `1e-8` rpm. Controlled-pacer unit tests exercised active pause/freeze, resume, stop, reset, restart, cancellation and disposal without wall-timer polling. Equivalent full scenario samples were identical at 0.25x and 1000x; only requested pacing delay changed. Rendered integration tests covered typed/atomic profile, revision and module import failures; a persistent 0.1-second deadline failure and negative `DYNAMICS_RUN_FAULTED` response; UI run reentrancy; and stale-run suppression across reset, close, reopen and delayed open. Headless numerical/integration coverage also accepts a finite but extreme torque/gear vector that overflows modeled power during launch. The engine rolls back to its last finite state/sample, marks the lifecycle Faulted, and the real v2 session returns a negative `DYNAMICS_RUN_FAULTED` response rather than encoding poisoned values. The rebuilt Windows Client was launched at `src/AutoForge.Client/bin/Release/net10.0-windows10.0.26100.0/win-x64/AutoForge.Client.exe` and operated through its local WebView2 session. Import of unknown profile, revision and module references showed recoverable error notices without changing the selected valid configuration. The short-deadline run visibly ended Faulted at step 101 / 10.1 model seconds; the failure remained visible after a dynamic diagnostic read and previously good telemetry rows were cleared. A valid baseline run completed at step 3,361 / 336.1 model seconds. The active runner was then paused and held at step 1 while waiting, resumed, stopped, explicitly stepped, reset to a new step-0 session, read 17 `SYNTHETIC_DYNAMIC` values at step 0, exported/re-imported the configuration, and closed. The `/diagnostics`, `/vehicle-profiles`, `/execution-targets`, `/`, and unmatched not-found routes loaded. The launched Client and its local DevTools listener were closed and verified absent afterward. The Step-04 worker report remains historical; the corrective evidence is in the [Step-04A report](../prompts/Step-04A-Report.md). Step-04/04A/04B are accepted. All model and telemetry values remain synthetic. ## Step-04B owner-drain corrective verification Start and resume now reject before changing lifecycle state when a previous advancement owner is still cleaning up after pause, stop or reset. The real simulation page reports that rejection as an error rather than a successful start/resume. Controlled barrier tests reproduced the prior defect: while the cancelled owner was held in cleanup, Pause-to-Resume changed `Paused` to `Running`, Stop-to-Start changed `Stopped` to `Running`, and Reset-to-Start changed `Stopped` at step 0 to `Running`. After the guard, all three complete status snapshots and sample counts remain unchanged on rejection; releasing cleanup then permits exactly one retry and one new fixed step. The final sequential Release build covered all nine solution projects and succeeded with zero warnings and zero errors. The full solution test command passed 126 unit and 81 integration tests (207 total; zero failed/skipped), preserving all 202 Step-04A cases. Focused owner-drain regressions passed 4 unit and 2 integration tests. See the [Step-04B corrective report](../prompts/Step-04B-Report.md) for exact commands and detailed contract evidence. The actual native Windows Client smoke exercised start, active pause/resume, stop/restart, reset, protocol-v2 telemetry read and close. It confirmed stable paused/stopped steps, a reset session at step 0, `SYNTHETIC_DYNAMIC` telemetry, and release of the closed session. This manual UI smoke does not claim to force the cleanup interleaving; that exact race is established by the controlled headless tests. The Client and its task-local WebView2 debug listener/profile were stopped and cleaned up. Step-04/04A/04B are accepted; the prior numerical thresholds and synthetic-only scope are unchanged. ## Step-05A live dashboard corrective verification The corrected dashboard is shared by the actual `/diagnostics` static-v1 and `/simulation` dynamics-v2 workflows. Focused headless checks passed: - `dotnet test .\src\tests\AutoForge.UnitTests\AutoForge.UnitTests.csproj --configuration Release --no-restore --filter FullyQualifiedName~LiveDashboardGaugeRenderingTests` — 7 passed, 0 failed, 0 skipped. - `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~LiveDashboard|FullyQualifiedName~RealApplicationAndRenderedRoute"` — 10 passed, 0 failed, 0 skipped. The selection includes controlled feed, actual static/dynamic provider, rendered panel, lifecycle and startup regression cases. - `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter FullyQualifiedName~RealApplicationAndRenderedRoute_RunAndReadDynamicTelemetryWithoutOracle` — 1 passed, 0 failed, 0 skipped; the real `/simulation` route renders the shared dashboard panel for an open dynamics session. The required sequential full commands were then run: ```powershell dotnet build .\src\AutoForge.slnx --configuration Release --no-restore dotnet test .\src\AutoForge.slnx --configuration Release --no-build ``` The build succeeded for all nine projects, including the native Windows Client, with 0 warnings and 0 errors. The MAUI XAML source-generation notice was informational. The complete suites passed 133 unit and 91 integration tests (224 total, 0 failed, 0 skipped), preserving the 207-case baseline and adding 17 dashboard-focused cases. The actual Windows Client smoke used .NET SDK 10.0.402/runtime 10.0.13, MAUI workload 10.0.403 / `maui-windows` manifest 10.0.110, Windows SDK target 10.0.26100.0 and WebView2 Runtime 156.0.4314.50. On `/diagnostics`, the worker explicitly imported and selected the synthetic truck/profile/provider, opened the static session, and started monitoring before selecting verified bindings. The native editor visibly rejected an invalid range and an `rpm` signal bound to `km/h` without adding a gauge or stopping the feed. A numeric gauge rendered 850 rpm; a bar first rendered 850 rpm below its configured range at 0% geometry, then after editing to 0..1000 rendered 85%. Removing it and hiding the remaining gauge did not stop polling. Stop/restart succeeded on the same session. Reset created a new session with a stopped empty dashboard and no prior gauge values; a fresh feed started on the replacement session, and close removed the panel. On `/simulation`, the actual v2 session was paused at step 1 / 0.1 model seconds. The dashboard rendered `SYNTHETIC_DYNAMIC` engine speed and vehicle speed with logical request ticks, model step/time, configuration fingerprint and run ID. After an explicit 200-step command, the readings updated to step 201 / 20.1 seconds (2,795 rpm and 19.7 m/s). Two later polls kept the paused model at step 201. Reset opened a new step-0 session/run with an empty stopped dashboard; the first new run sample displayed `dynamics-run-000002`, not the prior run. Close released the panel. The existing execution-target, profile, home and not-found routes loaded. Both temporary Client/WebView2 processes and their isolated user-data profiles were stopped/removed; loopback debug listeners were verified closed. See the [Step-05A corrective report](../prompts/Step-05A-Report.md) for the named controlled fault/lifecycle evidence and full acceptance mapping. After the final source-path cleanup, the rebuilt Client was launched again; actual static-v1 and dynamics-v2 sessions each reached dashboard cycle 1 and closed cleanly with the panel removed. ## Step-05B range and boundary verification The Uncertain projection now computes its range status independently of source quality. Before the fix, the real-provider regression failed on the actual Uncertain -10 rpm sample: expected `OutOfRangeLow`, actual `null`. After the fix, the focused unit suite passed 8 cases and the focused integration selection passed 3 cases, including real-provider Uncertain -10/1100 readings rendered through both numeric and bar gauges, Uncertain values at both exact bounds, atomic invalid-definition vectors, and controlled Stop-drain cleanup. The full post-fix Release build succeeded for all nine projects with 0 warnings and 0 errors; the MAUI XAML source-generation notice was informational. The full Release test suite passed 134 unit and 91 integration tests (225 total, 0 failed, 0 skipped). On the exact rebuilt native Client and an isolated WebView2 profile, the static editor configured a horizontal bar from the real `SYNTHETIC_STATIC` engine signal and displayed 850 rpm. The dynamics editor configured a numeric gauge from the real `SYNTHETIC_DYNAMIC` engine signal and displayed 260 rpm with logical tick, model step/time, configuration fingerprint and run identity; the model was paused at step 1 / 0.1 seconds. Both sessions closed with their dashboards, the exact test processes and port 9351 were verified stopped, and the isolated test profile was removed. The older shared WebView2 profile was left untouched. These native observations confirm the dashboard baseline; the Uncertain and malformed-input cases are established by controlled tests, not claimed as native UI injection. Step-05 with Step-05A and Step-05B was accepted by the orchestrator on 2026-10-29. These historical worker results remain distinct from that manual acceptance. ## Step-06 display-unit verification The shared shell defaults to Imperial (US) / Road and persists explicit Metric/Imperial (US) and Road/Engineering selections through the native MAUI Preferences adapter. Portable tests inject an isolated store; controlled read, write, corrupt-value and invalid-selection cases exercise the same application service without modifying platform preferences. Pure tests cover the specified forward/inverse conversion vectors, affine temperature bounds, finite/overflow handling, exact pass-through/unknown units and conversion before rounding. Rendered real-provider coverage toggles all speed modes repeatedly on a paused dynamics session and verifies unchanged source snapshots, gauge definitions, trace/request count, configuration export, model state and bar percentage. Current command outcomes and exact complete suite counts are recorded in the [Step-06 worker report](../prompts/Step-06-Report.md). Native persistence and draft-editor observations are reported separately from controlled storage failure/error tests; headless verification does not substitute for the actual Windows Client smoke. This section preserves the original Step-06 worker evidence; the subsequent Step-06A correction and current review status are recorded below. At that time, Step-07 recording had not yet run; replay remains outside Step-07 scope. The final sequential Release build completed all nine projects, including the Windows Client, with 0 warnings and 0 errors. The full suite passed 178 unit and 92 integration tests (270 total; 0 failed/skipped), preserving the accepted 225-case Step-05B baseline and adding 44 unit plus one integration case. Focused display-unit tests passed 44/44; the focused real static/dynamic/rendered integration selection passed 3/3. The rebuilt Windows Client was launched with task-local WebView2 debug port 9361 and an isolated temporary WebView profile. Its initial native shell showed the Imperial (US) / Road first-use default before any session; the key had no saved selection. A real static v1 session rendered 850 rpm unchanged after switching the shared selectors. A real dynamics v2 session was paused at step 203 / 20.3 seconds and returned 20.1168 m/s. Its bar displayed 45 mph / 0..90 mph, 66 ft/s / 0..132 ft/s, 72 km/h / 0..144.84096 km/h, and 20 m/s / 0..40.2336 m/s; all modes kept 50% geometry, the exact 20.1168 m/s source reading, and step 203. The native range editor saved 0..90 mph as canonical 0..40.2336 m/s. An open 10..110 mph draft retained its mph labels and values after the global system changed to Metric; saving produced source bounds 4.470400000000001..49.174400000000006 m/s and the equivalent Metric/Road display range. An invalid 200..100 range surfaced an alert and preserved the prior gauge; an unedited Save retained its exact existing source bounds. Protocol-v2 telemetry displayed Imperial numeric readings while retaining source `kg/s`, `N*m`, `degC` and exact source speed alongside them. Exported configuration remained 2,789 characters, contained the unchanged SI target 20.1168 and no display-unit labels, and kept its fingerprint. Reset opened a new stopped step-0 session/run with an empty dashboard; close released it. The native app was closed and reopened: Imperial (US) / Road restored as a saved choice. Existing diagnostics, execution-target, profile, home and not-found routes loaded without an error banner. Only the exact temporary WebView profile was removed; the preference created by this smoke was left at the sensible Imperial/Road default, and no unrelated preferences were changed. ## Step-06A corrective verification The original Step-06 review found invalid-selection initialization/storage mutation and unavailable/wrong-type readout presentation gaps. Step-06A closes those gaps without changing the approved defaults, mappings, editor policy, model/source data or protocol. Step-06 remains **not accepted** pending manual review; Step-07 had not yet run at that point. The final Step-07 evidence is recorded below. Before the fix, an invalid proposal on a fresh service loaded the saved `metric|road` selection instead of leaving the untouched default; store reads were not zero. The presentation regressions observed `"null"` for a null numeric measurement, echoed `"not a number"` for a string-valued `m/s` signal, and omitted an unconverted notice for unsupported-unit text. After the fix, `PreferenceService_RejectsInvalidChoiceBeforeInitializingOrReadingStore`, `RejectedSelectorEventReconcilesControlAndReadoutAndCanRetry` (both selectors), `DiagnosticRoute_RendersNullWrongTypeUnknownAndUnsupportedStaticV1SignalsTruthfully`, and `FormatSourceValue_PreservesJsonNullAndBooleanLexicalValues` pass as part of the full suite. Real-provider controlled tests cover converted Uncertain, Stale, Stopped and failed-display projections; protocol-v2 validation remains strict. The final sequential Release build completed all nine solution projects with 0 warnings and 0 errors; the MAUI XAML source-generation notice was informational. The complete suites passed 179 unit and 105 integration tests (284 total; 0 failed, 0 skipped), preserving the 270-case Step-06 baseline and adding 14 corrective cases. Exact final commands: - `dotnet build .\src\AutoForge.slnx --configuration Release --no-restore` - `dotnet test .\src\AutoForge.slnx --configuration Release --no-build` The rebuilt Windows Client smoke used the task-isolated WebView2 debug port 9361 and an isolated `LOCALAPPDATA`/WebView2 profile. First use showed Imperial (US) / Road. A real static v1 session rendered 850 rpm unchanged. A real paused v2 session at step 203 / 20.3 seconds retained exact source 20.1168 m/s while native readouts displayed 20.117 m/s, 72.420 km/h, 45.000 mph and 66.000 ft/s across all four selections. A native horizontal bar displayed 72 km/h from source 20.1168 m/s over 0–144.84096000000002 km/h with 50% geometry. Its open Metric/Road editor draft remained in km/h after the global selection changed to Imperial (US)/Engineering; closing and reopening the app restored the task-isolated Metric/Road preference. Both static and dynamics sessions closed and released their dashboards. The native smoke did not inject a platform storage failure or malformed v1 values. Those cases are covered by controlled store tests and the real static v1 rendered integration path, respectively. All native preference/profile data was written under the task-owned isolated profile; that exact profile was removed after both Client processes and port 9361 were closed. No unrelated user preference/profile data was changed. See the [Step-06A corrective worker report](../prompts/Step-06A-Report.md) for matrix-level evidence, limitations and preservation review. ## Step-07 bounded telemetry recording verification The final sequential Release build completed all nine solution projects, including the Windows Client, with zero warnings and zero errors. The MAUI XAML source-generation notice was informational. The full suite passed 179 unit and 124 integration tests (303 total; zero failed and zero skipped), preserving the Step-06A baseline of 284 and adding 19 integration regressions. The focused telemetry recording selection passed 19/19, including the cross-scope capture-retention regression. Commands: - `dotnet build .\src\AutoForge.slnx --configuration Release --no-restore` - `dotnet test .\src\AutoForge.slnx --configuration Release --no-build` - `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~TelemetryRecordingIntegrationTests"` The rebuilt Windows Client was launched with isolated task-owned WebView2 profiles and local DevTools ports. A static v1 session captured seven actual operations (including positive and no-response discovery, DTC and signal reads), closed with `SourceClosed`, saved locally, then was loaded after app restart. The readback showed `autoforge.synthetic-diagnostics v1`, endpoint `0x10`, raw request/response payloads, and two decoded source signals (`850 rpm` and `12.6 V`). A dynamics v2 session was paused at step 8 / 0.8 model seconds. With gauges hidden, two actual `read.signals` observations captured exact configuration/run and model step/time context. The panel was unmounted by navigating Home; the session close stopped the capture as `SourceClosed`, and its unsaved snapshot remained available on the dynamics route for explicit save. After another Client restart, both archives loaded and exposed raw bytes and decoded signals; the static capture had two signals and the dynamics capture had five. The displayed Metric/Road selection remained unchanged. That route-unmount smoke exposed a scoped-workspace lifetime bug; the workspace was changed to application-wide singleton lifetime and `CaptureWorkspace_IsSharedAcrossHostScopesAndRetainsClosedSourceCapture` regresses it. Native post-fix evidence confirms the capture survives unmount and source close. The UI also renders protocol versions and endpoint addresses without Razor interpolation artifacts. Controlled tests, not the native smoke, cover exact fixed limits, malformed archives, cancellation, collision and filesystem failures. The `LOCALAPPDATA` override isolated neither MAUI's `FileSystem.AppDataDirectory` nor display preferences on this Windows environment. The application initially listed zero archives; the two task-generated captures were written to its app-local `recordings` directory, then those exact IDs were removed after closing the Client. No pre-existing capture was overwritten or deleted. The WebView2 profiles were task-owned temporary directories and were removed. Metric/Road preferences were observed but not changed. See the [Step-07 worker report](../prompts/Step-07-Report.md) for frozen-matrix evidence, self-review and preservation details. Worker completion remains pending manual orchestrator review; no Step-08 work began. ## Step-07A corrective recording verification Step-07 remains historically **NOT ACCEPTED**; this correction preserves its 303-case baseline and native smoke evidence. Before the fixes, the focused recording selection ran 23 tests with 17 passing and 6 failing. The failures reproduced actual boundary defects: an empty `TransportOutcome.Response` was rejected before it could be archived; source-accepted case-variant identities were rejected on readback; a positive signal read with a null snapshot escaped as `NullReferenceException`; a stopped capture remained in the session registration list; an existing file used as the storage root listed as empty; and an actual panel save collision was followed by catalogue refresh, which replaced the visible save error with a malformed-archive error. The latter was also rerun against the real panel event before correction and failed because the rendered error no longer contained the collision message. After correction, `TelemetryRecordingIntegrationTests` passed 26/26. The tests exercise the actual v1/v2 observation and save/read paths, coherent raw-and- decoded v2 mutation cases, deterministic stop/error/limit registration release, invalid and missing storage roots, and the actual panel collision/error/retry flow. The full Release build completed all nine solution projects, including the Windows Client, with zero warnings and zero errors; the MAUI XAML source- generation notice was informational. The full suite passed 179 unit and 131 integration tests (310 total, zero failed and zero skipped). Exact commands: - `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --filter "FullyQualifiedName~TelemetryRecordingIntegrationTests"` (26/26) - `dotnet build .\src\AutoForge.slnx --configuration Release --no-restore` (nine projects; 0 warnings, 0 errors) - `dotnet test .\src\AutoForge.slnx --configuration Release --no-build` (179 unit + 131 integration; 310 total) The rebuilt Windows Client was exercised through its local WebView2 DevTools endpoint. Static v1 captured seven actual operations, then stopped/saved, closed its source, restarted the app, and loaded/inspected the archive. Dynamics v2 was paused at model step 7 / 0.7 seconds; with gauges hidden, it captured four actual `read.signals` operations, then stopped/saved, closed its source, restarted, and loaded/inspected the archive. Both readbacks exposed raw bytes and decoded signals/context; Metric/Road preferences remained unchanged. Native captures were `034e287ae82e4e14aa4d55e78581cbf1` (static) and `69def5834cf742ce9fa729dd4bea1b16` (dynamics). Those exact task-generated archive files and temporary WebView2/profile directories were removed after the Client and DevTools listener were closed. Native evidence verifies the normal record/stop/save/restart/load/source-close workflow; it does not claim native filesystem-fault injection. Invalid roots, save collisions, coherent malformed archives, and error/limit lifetime cleanup are covered by controlled integration tests. The `LOCALAPPDATA` override did not redirect MAUI `FileSystem.AppDataDirectory` in this environment. See the [Step-07A corrective worker report](../prompts/Step-07A-Report.md) for the frozen-matrix mapping, pre/post-fix outputs, self-review and preservation review. Step-08 remains blocked pending manual review; no Step-08 work began. ## Step-07B lock-safe session disposal verification The pre-fix reproduction used the real diagnostic protocol/session, capture and provider transport with a test-only subscription wrapper exposing controlled dispose barriers. It held a capture callback at limit or observation-error detach after the capture lock was released, started close/reset until its second unsubscribe was entered, then released the callback. Both actual tasks remained incomplete: `Operation completed=False; close/reset completed=False.` The two focused cases failed as expected after their five-second safety deadlines (two failed, zero passed); the bounded `dotnet test` host exited normally after reporting both cases, so no deadlocked process tree required termination. Command: `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --filter "FullyQualifiedName~SessionCloseDuringCaptureDetach_DoesNotDeadlockOrLoseFailurePrefix"` (exit 1). These are deterministic barrier-forced lock-cycle observations, not a stress-timing claim. The corrected session publishes one shared disposal completion and snapshots the lifetime resources under the lifetime gate, then performs cancellation and resource/control/transport disposal after releasing it. Concurrent callers observe the same task and cleanup error; late registration rejects once close ownership has been established. The focused set passed 29/29 recording tests, including limit-close and error-reset, exact prefix/reason preservation, replacement-session isolation, concurrent disposal and cleanup failure. Commands and results: - `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --filter "FullyQualifiedName~SessionCloseDuringCaptureDetach_DoesNotDeadlockOrLoseFailurePrefix|FullyQualifiedName~ConcurrentSessionDispose_SharesCompletionAndReportsCleanupFailure"` (3 passed) - `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --filter "FullyQualifiedName~TelemetryRecordingIntegrationTests"` (29 passed) - `dotnet build .\src\AutoForge.slnx --configuration Release --no-restore` (nine projects; 0 warnings, 0 errors) - `dotnet test .\src\AutoForge.slnx --configuration Release --no-build` (179 unit + 134 integration; 313 total, zero failed/skipped) The rebuilt Windows Client was rechecked through its local WebView2 DevTools endpoint. Static v1 recorded two actual operations (DTC and signal reads), stopped, closed its source while retaining the unsaved capture, then saved. After app restart, the archive loaded with its raw bytes and decoded signals. Dynamics v2 was explicitly stepped to model step 7 / 0.7 seconds, captured four actual `read.signals` observations with gauges hidden, then stopped and closed its source while retaining the unsaved capture before saving. A second app restart loaded both static and dynamics archives with raw data and decoded source/model context. Metric/Road preferences remained unchanged. The exact task-owned capture IDs were `3b6bbb098a094ac2ba10c042dcd4fbf0` (static) and `ac5b4d4e814d4905a0d454292b4dde87` (dynamics); their exact archive files and task-owned temporary profiles were removed after closing the Client. The controlled integration tests prove the close/reset lock-cycle resolution; the native smoke verifies unchanged normal record/stop/close/save/restart/ readback behavior and does not claim native race injection. See the [Step-07B worker report](../prompts/Step-07B-Report.md) for matrix mapping, post-green source review and preservation checks. Step-07/07A remain NOT ACCEPTED pending manual review; Step-08 remains blocked and was not started.