6.8 KiB
Verified synthetic calibration comparison
Step-13 is implemented pending manual review. This is a narrow synthetic comparison, not manufacturer prediction, safe tuning advice, firmware proof, physical authority or a general AI/runbook executor.
Explicit connected workflow
- Create/select the original warm configuration and authoring Baseline. Optionally record an actual original warm run through ordinary diagnostics.
- In
/runbooks, explicitly validate manual input or original content from the qualified local model. The decisive goal is warm idle 1250 rpm and 2000-rpm torque 350 N*m; keep every other value unchanged. - Return to
/calibration; explicitly copy the exact current preview into this existing pinned draft. Copy validates workspace/head/configuration and keeps canonical doubles and the draft's prior units. Save separately. - Select the isolated rehearsal provider, Open, prepare original two-read backup, prepare exact current Proposed Apply, explicitly confirm/Approve, Dispatch and inspect independent complete readback.
- Open comparison controls explicitly, select THIS owning verified Apply and
autoforge.simulation.dynamics, then Evaluate. This does not program a target, overwrite a configuration/run or promote Proposed to Tested/Approved. - Inspect/copy the canonical readonly report. Save both captures explicitly.
Only persisted/readback-verified IDs qualify as saved evidence. Open each
exact ID in existing
/telemetry-replay, inspect prefix/end/raw bytes and immutable original provenance. Replay is archive playback, not physics.
No action is implied by rendering, navigation, AI validation, unit changes or notifications. Manual validation remains available without a local model.
Trusted proof and exact immutable mapping
An actual idle Ready owning rehearsal must have an original verified backup and current verified Apply (including genuine post-reconciliation verification). Admission freshly reads the full target and matches exact instance/source/ revision/operation/approval/backup/workspace/head/definition, candidate and every changed/unchanged value. Original backup must equal original supported config values. Caller success records cannot construct the internal proof capability. RecoveryRequired, divergent/unavailable, wrong/closed/stale evidence rejects.
The pure supported mapping changes only Model.WarmIdleTargetRpm and torque cells. Axis, every other model field, initial conditions, five-phase scenario and profile/module/model/calibration references remain unchanged. Existing constructors/validation/fingerprints/catalogue register the NEW immutable config; original config and authoring binding/history are not rebased. No-change mapping truthfully retains the same content fingerprint, not a fabricated improvement.
Proof is historical at its readback time, not perpetual external target attestation. Owning source guards run between scenarios, and another fresh full readback plus current-head/lifetime checks precede atomic result publication.
Equivalent acquisition and metrics
Two fresh sequential real Simulation/v2 diagnostic sessions use equivalent initial state/scenario and distinct run/capture IDs. Physics advances only through real StepAsync(1). Engine AND transmission signals are read every five completed steps plus completion, without duplicate final reads. At 0.1 s/step this is 0.5 virtual-second cadence. Maximum is 3900 steps/run and 1562 scheduled observations; a model needing step 3901 rejects as incomplete. Existing archive bounds remain 4096 observations, 16 MiB observations, 1 MiB header, 32 MiB archive. Independent accepted capture APIs leave ordinary unsaved recordings untouched.
Metrics use exact Good finite canonical module/run/config/step/time values. Missing, non-Good, wrong-unit/context/nonfinite replies cannot become zero. At least TEN actual warm samples are required; last ten must each be within 1 rpm of their target and 0.001 m/s of stationary. A shorter window is incomplete. Report includes warm/error/stationary, model/phase step counts, acceleration/ braking time, sampled cruise count/range, fuel/distance deltas from initial state, total virtual time and final actual transmission.shift-count.
The decisive original/derived pair both completes 3361 steps/336.1 s with phase counts 100/103/3000/58/100, acceleration 10.3 s and braking 5.8 s. The 3000 cruise model steps remain independently tested within 45 MPH +/-1 MPH; production reports 600 sampled cruise signal sets at 20.1168 m/s. Last-ten idle errors are below 1e-8 rpm with zero stationary speed for 650 and 1250 rpm. Measured fuel is 0.518385971679477 versus 0.5184897031483956 kg; distance 6193.507764002321 versus 6193.389583605566 m; final shift count 4 versus 4. No beneficial sign is promised. Sampled range is not continuous extrema; final count is not an exact shift timeline. Request/capture elapsed, diagnostic ticks and virtual model time are different clocks.
The readonly canonical report identifies proof/time/preparation/backup/mutation/ approval/source/head/definition/model/module/profile, exact torque before/after, original/derived fingerprints, providers/run/capture IDs, completion and metrics. Display preferences never alter source/report/archive values.
Lifetime, partial evidence and save
One admitted comparison/run/save owner rejects competing requests Busy before starting another. Hybrid callbacks return promptly; admitted work runs off the UI dispatcher. Cancel/Close/unmount drains owned diagnostics/capture resources outside required gates, preventing late healthy publication. New evaluation/ Close retires earlier current status; source/head/proof supersession labels it Stale/as-of without rebase. One previous success and bounded latest partial run/ save evidence remain inspectable, not an unbounded history.
Failed/limited/cancelled physics never becomes a successful pair. A stopped capture can represent complete coverage of a partial run; the run's separate error/metrics/completion determine comparison success. This does not expand or mislabel archive-v1 stop-reason semantics.
Pair save is NOT atomic. Each capture uses existing no-overwrite publication and exact serialized fresh readback. If one fails, successful files and unsaved capture remain; UI identifies persisted/verified/error per ID. Retry skips verified captures and only saves missing work. If a failed publication/cleanup may have left a file, retry checks the catalogue and verifies it read-only. Mismatched/corrupt readback remains an error; there is no overwrite, rollback deletion, hidden new ID or fake all-saved state.
See authoring, rehearsal, runbooks, recording, replay and build/test evidence.