430 lines
26 KiB
Markdown
430 lines
26 KiB
Markdown
# Build and test
|
|
|
|
## Prerequisites
|
|
|
|
- Windows x64, .NET SDK 10.0.402 with its approved .NET 10 patch roll-forward.
|
|
- Windows SDK target 10.0.26100.0 and MAUI Windows workload manifest 10.0.110.
|
|
- Microsoft Edge WebView2 Runtime to launch the native Blazor Hybrid Client.
|
|
|
|
The previously verified environment reported runtime 10.0.13, MAUI workload
|
|
version 10.0.403 as listed by the installed SDK, and WebView2 Runtime
|
|
155.0.4283.62. The Client targets `net10.0-windows10.0.26100.0` and `win-x64`.
|
|
All other projects target portable `net10.0`; tests do not require MAUI or
|
|
WebView2.
|
|
|
|
## Restore, build, test and launch
|
|
|
|
From the repository root in PowerShell, run the full build and both suites
|
|
sequentially:
|
|
|
|
```powershell
|
|
dotnet restore .\src\AutoForge.slnx
|
|
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
|
|
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
|
|
dotnet run --project .\src\AutoForge.Client\AutoForge.Client.csproj --configuration Release --framework net10.0-windows10.0.26100.0
|
|
```
|
|
|
|
The build includes the actual native Client and all nine solution projects.
|
|
For an explicit Windows runtime pack restore or direct native build:
|
|
|
|
```powershell
|
|
dotnet restore .\src\AutoForge.Client\AutoForge.Client.csproj --runtime win-x64
|
|
dotnet build .\src\AutoForge.Client\AutoForge.Client.csproj --configuration Release --framework net10.0-windows10.0.26100.0 --no-restore
|
|
```
|
|
|
|
Do not pass Windows TFM overrides to the portable test projects. The Client
|
|
contains the real UI RCL in a native MAUI BlazorWebView. No automotive driver,
|
|
actual vehicle, database, backend, model or cloud account is required.
|
|
|
|
## Focused tests
|
|
|
|
```powershell
|
|
dotnet test .\src\tests\AutoForge.UnitTests\AutoForge.UnitTests.csproj --configuration Release
|
|
dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release
|
|
```
|
|
|
|
The unit suite covers existing Core/Application behavior, rendered generic
|
|
components, profile invariants and strict codec behavior, plus protocol v1
|
|
round-trip/snapshot contracts and bounded trace behavior. The integration suite
|
|
loads source-controlled profile fixtures through real DI, opens actual
|
|
simulation sessions, sends/decodes requests through the transport, verifies
|
|
identity/DTC/static signals, virtual clear/readback/reset and independent
|
|
session state, exercises deterministic malformed/no-response/timeout/cancelled
|
|
faults, renders the diagnostic route against the actual provider, and checks
|
|
the nine-project reference graph. Fixtures are never treated as real vehicle
|
|
definitions. The internal state oracle is exposed only to the integration-test
|
|
assembly.
|
|
|
|
The accepted Step-02A baseline was 103 unit plus 37 integration tests (140
|
|
total). The Step-03 worker report records the full, expanded counts, warnings,
|
|
commands and native observations; do not infer acceptance from these earlier
|
|
runs. Historical Step-02 had 59 unit and 34 integration cases; it predates the
|
|
Step-02A corrections. See the [Step-02 report](../prompts/Step-02-Report.md) and
|
|
[Step-02A report](../prompts/Step-02A-Report.md) for historical evidence.
|
|
|
|
Step-03 worker verification ran the nine-project Release build with zero
|
|
warnings/errors, then passed 108 unit and 53 integration cases (161 total,
|
|
zero failed/skipped). Its native smoke used the actual Windows Client and
|
|
verified explicit synthetic selection, module probes/identity, DTC and static
|
|
signals, raw request/reply trace, virtual clear/readback/reset, close, target
|
|
metadata, profile, home and not-found routes. Exact observations and limitations
|
|
are recorded in the [Step-03 worker report](../prompts/Step-03-Report.md);
|
|
the run did not cover the subsequently identified integrity findings and Step-03
|
|
was not accepted.
|
|
|
|
Step-03A added actual failing-before/passing-after regressions for missing and
|
|
duplicate request fields, semantic response validation/trace consistency, and
|
|
clear acknowledgement versus verified readback. The final sequential Release
|
|
verification passed 111 unit tests and 64 integration tests (175 total, zero
|
|
failed/skipped), preserving the original 161 cases plus 14 additional test
|
|
cases. Exact commands and outcome details are in the
|
|
[Step-03A corrective report](../prompts/Step-03A-Report.md). Manual
|
|
orchestrator acceptance remains pending.
|
|
|
|
Step-03B reproduced the probe-only identity-loss defect before the fix through
|
|
the real Simulation transport: the regression expected a positive probe but
|
|
observed a negative discovery outcome. After the correction, the focused
|
|
protocol/UI integration selection passed 35 cases. The complete nine-project
|
|
Release build passed with zero warnings and errors, and the complete suite
|
|
passed 111 unit plus 72 integration tests (183 total, zero failed/skipped),
|
|
preserving all 175 Step-03A cases. Exact commands and AC mapping are recorded in
|
|
the [Step-03B corrective report](../prompts/Step-03B-Report.md).
|
|
|
|
The native Windows Client was launched and the operational baseline was
|
|
exercised in its own WebView: explicit example import/profile/revision/provider/
|
|
Simulation selection, session open, discovery with expected/probe/identity
|
|
counts, configured transmission no-response, engine DTC/static-signal reads,
|
|
verified clear with fresh empty readback, raw/decoded trace, reset with initial
|
|
DTC restoration, close, and `/execution-targets`, `/vehicle-profiles`, `/`,
|
|
and not-found routes. Exact observations and limitations are in the
|
|
[Step-03B corrective report](../prompts/Step-03B-Report.md). Native interaction
|
|
used a session-local WebView debug port on the worker-launched Client; partial
|
|
identity remains covered by real-DI rendered tests because the shipped native
|
|
configuration has no fault selector for that scenario.
|
|
|
|
## Step-04 fixed-step dynamics verification
|
|
|
|
The Step-04 Release regression ran sequentially against the full solution:
|
|
|
|
```powershell
|
|
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
|
|
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
|
|
```
|
|
|
|
The native Windows-targeted build covered all nine solution projects with zero
|
|
warnings/errors. The complete test command passed 115 unit and 75 integration
|
|
tests (190 total, zero failed/skipped), preserving the Step-03B 183-test
|
|
baseline. The unit numerical gate executes 3,361 deterministic 0.1-second
|
|
samples and compares full sampled state across equal runs. The baseline results
|
|
were: 10.0 s warm idle at 650.000 rpm; acceleration to 20.1473 m/s in 10.3 s
|
|
with four scheduled shifts; all 3,000 cruise samples inside the configured
|
|
45-MPH +/- 1-MPH band and fully coupled; braking to 0.0000 m/s in 5.8 s; 10.0 s
|
|
return idle; and 0.518387 kg modeled total fuel. These are synthetic model
|
|
outputs, not measured vehicle performance or manufacturer predictions.
|
|
|
|
The actual Windows Client was launched with WebView2 local DevTools enabled for
|
|
the native smoke. `/simulation` required explicit selection of profile
|
|
`autoforge.synthetic.test-truck` revision 1, provider
|
|
`autoforge.simulation.dynamics`, and a configuration with fingerprint
|
|
`sha256:v1:e8991ae139b54959ec53a4fe64b08dc9bfc03feb533496cf741f2c9f3a2342da`.
|
|
Export/import preserved that fingerprint. A stopped open session returned 17
|
|
protocol-v2 dynamic telemetry values at step 4 / 0.4 model seconds after explicit
|
|
start/pause/step controls. The accelerated full scenario completed at step
|
|
3,361 / 336.1 model seconds with 17 telemetry values and four shifts. Invalid
|
|
`{}` import visibly reported the missing required `formatVersion`; exact-config
|
|
reset opened a new session at step 0 with the same fingerprint, and close
|
|
released it.
|
|
|
|
The native `/diagnostics` regression separately selected the original
|
|
`autoforge.simulation.synthetic` provider, discovered two positive probes out
|
|
of three expected endpoints (the transmission remained configured no-response),
|
|
and read the original engine DTC plus static 850-rpm and 12.6-V signals through
|
|
protocol v1 with trace records. The session was closed. Native route smoke
|
|
covered `/execution-targets` (both providers remain metadata), `/vehicle-profiles`,
|
|
`/`, and an unmatched not-found route. Numerical fidelity and reproducibility
|
|
are established by headless tests, not by visual telemetry.
|
|
|
|
## Native synthetic diagnostics smoke
|
|
|
|
Launch the actual Windows Client and visit `/diagnostics`:
|
|
|
|
1. Confirm the page starts without selecting/importing a profile or opening a
|
|
session. Click **Load synthetic truck example**; verify the profile appears
|
|
as an available revision but remains unselected.
|
|
2. Explicitly select `autoforge.synthetic.test-truck`, revision `1`, provider
|
|
`autoforge.simulation.synthetic`, and kind `Simulation`. Click **Open
|
|
simulation session** and confirm the visible session/profile/provider/
|
|
configuration identity. The session opens in process only.
|
|
3. Click **Probe virtual modules**. Engine/body respond; the configured
|
|
transmission endpoint visibly reports no response and is not reported as an
|
|
actual responder. Inspect the identity and declared implemented services.
|
|
4. Read the engine's DTCs and static signals. Values are synthetic static
|
|
snapshots with source, unit, quality and logical tick. Expand the bounded
|
|
trace to inspect actual request/response JSON and correlation values.
|
|
5. Clear the supported engine virtual DTCs, confirm the fresh readback is empty,
|
|
and confirm the UI explicitly states that no physical write occurred. Other
|
|
module/session state is isolated.
|
|
6. Exercise a visible deterministic failure (for example the configured
|
|
transmission no-response), then reset to the initial synthetic state and
|
|
close the session. Closing releases that session's trace and virtual state.
|
|
7. Separately visit `/execution-targets`, `/vehicle-profiles`, `/`, and an
|
|
unmatched route. Confirm metadata selection remains separate from an
|
|
operational session and the not-found/navigation behavior remains.
|
|
|
|
The Step-03A report records actual native baseline smoke separately from
|
|
headless rendered fault tests. The native Client revalidated explicit
|
|
profile/provider selection, successful clear with fresh empty readback,
|
|
trace/raw frames, visible no-response, reset/initial-state restoration, close
|
|
and existing routes. A deliberately false clear acknowledgement was injected
|
|
only in the rendered integration composition; the production Client has no UI
|
|
fault selector, so this is not native fault-injection evidence.
|
|
|
|
## Profile-schema and safety boundaries
|
|
|
|
See the [schema-v1 guide](vehicle-profile-schema-v1.md) for field, identity,
|
|
unknown-value, capability, provenance and strict JSON rules. Important invariants:
|
|
|
|
- Every v1 field is required; unknown optional facts are explicit JSON `null`.
|
|
Unknown fields and duplicate/case-ambiguous properties are rejected.
|
|
- Catalog selection requires exact `(profileIdentifier, revision)`. Duplicate
|
|
imports do not replace entries, and failed parsing cannot partially register.
|
|
- `publishedAt`/`retrievedAt` accept null or complete
|
|
`YYYY-MM-DDTHH:mm:ss[.fraction](Z|+HH:mm|-HH:mm)` timestamps only. The exact
|
|
fractional and offset limits and no-default policy are in the schema guide.
|
|
- A null optional module identity in evidence is an absent constraint. Any
|
|
supplied identity must match a known module value; an unknown target or
|
|
mismatch is rejected without identity inference.
|
|
- Imported profiles and capability/provenance statements are immutable
|
|
metadata, not connection, compatibility, a working service or authorization.
|
|
- Data remains in memory for the process only. JSON import/export does not write
|
|
files or timestamps implicitly.
|
|
- Static synthetic diagnostics use the [protocol v1 guide](synthetic-diagnostics-v1.md)
|
|
and [simulation definitions](simulation.md); dynamic output uses the separate
|
|
documented protocol-v2 provider. Neither is a real vehicle adapter, telemetry
|
|
capture, replay provider, calibration/firmware editor or hardware write path.
|
|
|
|
## Step-04A corrective verification
|
|
|
|
Step-04A corrects typed import errors for unavailable profile/revision/module or
|
|
conflicting calibration references, enforces the supported coupled RPM/redline
|
|
envelope, and makes progress, terminal failure and asynchronous runner ownership
|
|
explicit. It adds seven unit and five integration cases over the 190-case
|
|
Step-04 baseline. The final sequential commands were:
|
|
|
|
`dotnet build .\src\AutoForge.slnx --configuration Release --no-restore`
|
|
|
|
`dotnet test .\src\AutoForge.slnx --configuration Release --no-build`
|
|
|
|
The nine-project Windows Release build succeeded with zero warnings and zero
|
|
errors. The full test command passed 122 unit and 80 integration tests (202
|
|
total; zero failed/skipped). The warm baseline remains reproducible at 3,361
|
|
samples / 336.1 virtual seconds; 10.0 s warm idle at 650 rpm, 10.3 s acceleration
|
|
to 20.1473 m/s with four shifts, all 3,000 cruise samples in the original
|
|
45-MPH +/- 1-MPH band while coupled, braking to 0.0000 m/s in 5.8 s, 10.0 s
|
|
return idle, and 0.518387 kg modeled fuel. The added independent constant-torque
|
|
force/mass equation and speed-step equation checks use a `1e-10` acceleration
|
|
tolerance; independent locked RPM checks use `1e-8` rpm.
|
|
|
|
Controlled-pacer unit tests exercised active pause/freeze, resume, stop, reset,
|
|
restart, cancellation and disposal without wall-timer polling. Equivalent full
|
|
scenario samples were identical at 0.25x and 1000x; only requested pacing delay
|
|
changed. Rendered integration tests covered typed/atomic profile, revision and
|
|
module import failures; a persistent 0.1-second deadline failure and negative
|
|
`DYNAMICS_RUN_FAULTED` response; UI run reentrancy; and stale-run suppression
|
|
across reset, close, reopen and delayed open.
|
|
|
|
Headless numerical/integration coverage also accepts a finite but extreme
|
|
torque/gear vector that overflows modeled power during launch. The engine
|
|
rolls back to its last finite state/sample, marks the lifecycle Faulted, and the
|
|
real v2 session returns a negative `DYNAMICS_RUN_FAULTED` response rather than
|
|
encoding poisoned values.
|
|
|
|
The rebuilt Windows Client was launched at
|
|
`src/AutoForge.Client/bin/Release/net10.0-windows10.0.26100.0/win-x64/AutoForge.Client.exe`
|
|
and operated through its local WebView2 session. Import of unknown profile,
|
|
revision and module references showed recoverable error notices without
|
|
changing the selected valid configuration. The short-deadline run visibly ended
|
|
Faulted at step 101 / 10.1 model seconds; the failure remained visible after a
|
|
dynamic diagnostic read and previously good telemetry rows were cleared. A
|
|
valid baseline run completed at step 3,361 / 336.1 model seconds. The active
|
|
runner was then paused and held at step 1 while waiting, resumed, stopped,
|
|
explicitly stepped, reset to a new step-0 session, read 17 `SYNTHETIC_DYNAMIC`
|
|
values at step 0, exported/re-imported the configuration, and closed. The
|
|
`/diagnostics`, `/vehicle-profiles`, `/execution-targets`, `/`, and unmatched
|
|
not-found routes loaded. The launched Client and its local DevTools listener
|
|
were closed and verified absent afterward.
|
|
|
|
The Step-04 worker report remains historical; the corrective evidence is in the
|
|
[Step-04A report](../prompts/Step-04A-Report.md). Step-04/04A/04B are accepted.
|
|
All model and telemetry values remain synthetic.
|
|
|
|
## Step-04B owner-drain corrective verification
|
|
|
|
Start and resume now reject before changing lifecycle state when a previous
|
|
advancement owner is still cleaning up after pause, stop or reset. The real
|
|
simulation page reports that rejection as an error rather than a successful
|
|
start/resume. Controlled barrier tests reproduced the prior defect: while the
|
|
cancelled owner was held in cleanup, Pause-to-Resume changed `Paused` to
|
|
`Running`, Stop-to-Start changed `Stopped` to `Running`, and Reset-to-Start
|
|
changed `Stopped` at step 0 to `Running`. After the guard, all three complete
|
|
status snapshots and sample counts remain unchanged on rejection; releasing
|
|
cleanup then permits exactly one retry and one new fixed step.
|
|
|
|
The final sequential Release build covered all nine solution projects and
|
|
succeeded with zero warnings and zero errors. The full solution test command
|
|
passed 126 unit and 81 integration tests (207 total; zero failed/skipped),
|
|
preserving all 202 Step-04A cases. Focused owner-drain regressions passed 4
|
|
unit and 2 integration tests. See the [Step-04B corrective report](../prompts/Step-04B-Report.md)
|
|
for exact commands and detailed contract evidence.
|
|
|
|
The actual native Windows Client smoke exercised start, active pause/resume,
|
|
stop/restart, reset, protocol-v2 telemetry read and close. It confirmed stable
|
|
paused/stopped steps, a reset session at step 0, `SYNTHETIC_DYNAMIC` telemetry,
|
|
and release of the closed session. This manual UI smoke does not claim to force
|
|
the cleanup interleaving; that exact race is established by the controlled
|
|
headless tests. The Client and its task-local WebView2 debug listener/profile
|
|
were stopped and cleaned up. Step-04/04A/04B are accepted; the prior numerical
|
|
thresholds and synthetic-only scope are unchanged.
|
|
|
|
## Step-05A live dashboard corrective verification
|
|
|
|
The corrected dashboard is shared by the actual `/diagnostics` static-v1 and
|
|
`/simulation` dynamics-v2 workflows. Focused headless checks passed:
|
|
|
|
- `dotnet test .\src\tests\AutoForge.UnitTests\AutoForge.UnitTests.csproj --configuration Release --no-restore --filter FullyQualifiedName~LiveDashboardGaugeRenderingTests`
|
|
— 7 passed, 0 failed, 0 skipped.
|
|
- `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~LiveDashboard|FullyQualifiedName~RealApplicationAndRenderedRoute"`
|
|
— 10 passed, 0 failed, 0 skipped. The selection includes controlled feed,
|
|
actual static/dynamic provider, rendered panel, lifecycle and startup
|
|
regression cases.
|
|
- `dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter FullyQualifiedName~RealApplicationAndRenderedRoute_RunAndReadDynamicTelemetryWithoutOracle`
|
|
— 1 passed, 0 failed, 0 skipped; the real `/simulation` route renders the
|
|
shared dashboard panel for an open dynamics session.
|
|
|
|
The required sequential full commands were then run:
|
|
|
|
```powershell
|
|
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
|
|
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
|
|
```
|
|
|
|
The build succeeded for all nine projects, including the native Windows Client,
|
|
with 0 warnings and 0 errors. The MAUI XAML source-generation notice was
|
|
informational. The complete suites passed 133 unit and 91 integration tests
|
|
(224 total, 0 failed, 0 skipped), preserving the 207-case baseline and adding
|
|
17 dashboard-focused cases.
|
|
|
|
The actual Windows Client smoke used .NET SDK 10.0.402/runtime 10.0.13, MAUI
|
|
workload 10.0.403 / `maui-windows` manifest 10.0.110, Windows SDK target
|
|
10.0.26100.0 and WebView2 Runtime 156.0.4314.50. On `/diagnostics`, the worker
|
|
explicitly imported and selected the synthetic truck/profile/provider, opened
|
|
the static session, and started monitoring before selecting verified bindings.
|
|
The native editor visibly rejected an invalid range and an `rpm` signal bound
|
|
to `km/h` without adding a gauge or stopping the feed. A numeric gauge rendered
|
|
850 rpm; a bar first rendered 850 rpm below its configured range at 0% geometry,
|
|
then after editing to 0..1000 rendered 85%. Removing it and hiding the remaining
|
|
gauge did not stop polling. Stop/restart succeeded on the same session. Reset
|
|
created a new session with a stopped empty dashboard and no prior gauge values;
|
|
a fresh feed started on the replacement session, and close removed the panel.
|
|
|
|
On `/simulation`, the actual v2 session was paused at step 1 / 0.1 model seconds.
|
|
The dashboard rendered `SYNTHETIC_DYNAMIC` engine speed and vehicle speed with
|
|
logical request ticks, model step/time, configuration fingerprint and run ID.
|
|
After an explicit 200-step command, the readings updated to step 201 /
|
|
20.1 seconds (2,795 rpm and 19.7 m/s). Two later polls kept the paused model at
|
|
step 201. Reset opened a new step-0 session/run with an empty stopped dashboard;
|
|
the first new run sample displayed `dynamics-run-000002`, not the prior run.
|
|
Close released the panel. The existing execution-target, profile, home and
|
|
not-found routes loaded. Both temporary Client/WebView2 processes and their
|
|
isolated user-data profiles were stopped/removed; loopback debug listeners were
|
|
verified closed. See the [Step-05A corrective report](../prompts/Step-05A-Report.md)
|
|
for the named controlled fault/lifecycle evidence and full acceptance mapping.
|
|
After the final source-path cleanup, the rebuilt Client was launched again;
|
|
actual static-v1 and dynamics-v2 sessions each reached dashboard cycle 1 and
|
|
closed cleanly with the panel removed.
|
|
|
|
## Step-05B range and boundary verification
|
|
|
|
The Uncertain projection now computes its range status independently of source
|
|
quality. Before the fix, the real-provider regression failed on the actual
|
|
Uncertain -10 rpm sample: expected `OutOfRangeLow`, actual `null`. After the
|
|
fix, the focused unit suite passed 8 cases and the focused integration selection
|
|
passed 3 cases, including real-provider Uncertain -10/1100 readings rendered
|
|
through both numeric and bar gauges, Uncertain values at both exact bounds,
|
|
atomic invalid-definition vectors, and controlled Stop-drain cleanup.
|
|
|
|
The full post-fix Release build succeeded for all nine projects with 0 warnings
|
|
and 0 errors; the MAUI XAML source-generation notice was informational. The full
|
|
Release test suite passed 134 unit and 91 integration tests (225 total, 0
|
|
failed, 0 skipped).
|
|
|
|
On the exact rebuilt native Client and an isolated WebView2 profile, the static
|
|
editor configured a horizontal bar from the real `SYNTHETIC_STATIC` engine
|
|
signal and displayed 850 rpm. The dynamics editor configured a numeric gauge
|
|
from the real `SYNTHETIC_DYNAMIC` engine signal and displayed 260 rpm with
|
|
logical tick, model step/time, configuration fingerprint and run identity; the
|
|
model was paused at step 1 / 0.1 seconds. Both sessions closed with their
|
|
dashboards, the exact test processes and port 9351 were verified stopped, and
|
|
the isolated test profile was removed. The older shared WebView2 profile was
|
|
left untouched. These native observations confirm the dashboard baseline; the
|
|
Uncertain and malformed-input cases are established by controlled tests, not
|
|
claimed as native UI injection.
|
|
|
|
Step-05 with Step-05A and Step-05B was accepted by the orchestrator on
|
|
2026-10-29. These historical worker results remain distinct from that manual
|
|
acceptance.
|
|
|
|
## Step-06 display-unit verification
|
|
|
|
The shared shell defaults to Imperial (US) / Road and persists explicit
|
|
Metric/Imperial (US) and Road/Engineering selections through the native MAUI
|
|
Preferences adapter. Portable tests inject an isolated store; controlled read,
|
|
write, corrupt-value and invalid-selection cases exercise the same application
|
|
service without modifying platform preferences. Pure tests cover the specified
|
|
forward/inverse conversion vectors, affine temperature bounds, finite/overflow
|
|
handling, exact pass-through/unknown units and conversion before rounding.
|
|
Rendered real-provider coverage toggles all speed modes repeatedly on a paused
|
|
dynamics session and verifies unchanged source snapshots, gauge definitions,
|
|
trace/request count, configuration export, model state and bar percentage.
|
|
|
|
Current command outcomes and exact complete suite counts are recorded in the
|
|
[Step-06 worker report](../prompts/Step-06-Report.md). Native persistence and
|
|
draft-editor observations are reported separately from controlled storage
|
|
failure/error tests; headless verification does not substitute for the actual
|
|
Windows Client smoke. Step-07 recording/replay remains unimplemented and
|
|
blocked pending manual Step-06 review.
|
|
|
|
The final sequential Release build completed all nine projects, including the
|
|
Windows Client, with 0 warnings and 0 errors. The full suite passed 178 unit and
|
|
92 integration tests (270 total; 0 failed/skipped), preserving the accepted
|
|
225-case Step-05B baseline and adding 44 unit plus one integration case. Focused
|
|
display-unit tests passed 44/44; the focused real static/dynamic/rendered
|
|
integration selection passed 3/3.
|
|
|
|
The rebuilt Windows Client was launched with task-local WebView2 debug port 9361
|
|
and an isolated temporary WebView profile. Its initial native shell showed the
|
|
Imperial (US) / Road first-use default before any session; the key had no saved
|
|
selection. A real static v1 session rendered 850 rpm unchanged after switching
|
|
the shared selectors. A real dynamics v2 session was paused at step 203 /
|
|
20.3 seconds and returned 20.1168 m/s. Its bar displayed 45 mph / 0..90 mph,
|
|
66 ft/s / 0..132 ft/s, 72 km/h / 0..144.84096 km/h, and 20 m/s /
|
|
0..40.2336 m/s; all modes kept 50% geometry, the exact 20.1168 m/s source
|
|
reading, and step 203.
|
|
|
|
The native range editor saved 0..90 mph as canonical 0..40.2336 m/s. An open
|
|
10..110 mph draft retained its mph labels and values after the global system
|
|
changed to Metric; saving produced source bounds
|
|
4.470400000000001..49.174400000000006 m/s and the equivalent Metric/Road
|
|
display range. An invalid 200..100 range surfaced an alert and preserved the
|
|
prior gauge; an unedited Save retained its exact existing source bounds.
|
|
Protocol-v2 telemetry displayed Imperial numeric readings while retaining
|
|
source `kg/s`, `N*m`, `degC` and exact source speed alongside them. Exported
|
|
configuration remained 2,789 characters, contained the unchanged SI target
|
|
20.1168 and no display-unit labels, and kept its fingerprint. Reset opened a
|
|
new stopped step-0 session/run with an empty dashboard; close released it.
|
|
The native app was closed and reopened: Imperial (US) / Road restored as a
|
|
saved choice. Existing diagnostics, execution-target, profile, home and
|
|
not-found routes loaded without an error banner. Only the exact temporary
|
|
WebView profile was removed; the preference created by this smoke was left at
|
|