35 KiB
Build and test
Prerequisites
- Windows x64, .NET SDK 10.0.402 with its approved .NET 10 patch roll-forward.
- Windows SDK target 10.0.26100.0 and MAUI Windows workload manifest 10.0.110.
- Microsoft Edge WebView2 Runtime to launch the native Blazor Hybrid Client.
The previously verified environment reported runtime 10.0.13, MAUI workload
version 10.0.403 as listed by the installed SDK, and WebView2 Runtime
155.0.4283.62. The Client targets net10.0-windows10.0.26100.0 and win-x64.
All other projects target portable net10.0; tests do not require MAUI or
WebView2.
Restore, build, test and launch
From the repository root in PowerShell, run the full build and both suites sequentially:
dotnet restore .\src\AutoForge.slnx
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
dotnet run --project .\src\AutoForge.Client\AutoForge.Client.csproj --configuration Release --framework net10.0-windows10.0.26100.0
The build includes the actual native Client and all nine solution projects. For an explicit Windows runtime pack restore or direct native build:
dotnet restore .\src\AutoForge.Client\AutoForge.Client.csproj --runtime win-x64
dotnet build .\src\AutoForge.Client\AutoForge.Client.csproj --configuration Release --framework net10.0-windows10.0.26100.0 --no-restore
Do not pass Windows TFM overrides to the portable test projects. The Client contains the real UI RCL in a native MAUI BlazorWebView. No automotive driver, actual vehicle, database, backend, model or cloud account is required.
Focused tests
dotnet test .\src\tests\AutoForge.UnitTests\AutoForge.UnitTests.csproj --configuration Release
dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release
The unit suite covers existing Core/Application behavior, rendered generic components, profile invariants and strict codec behavior, plus protocol v1 round-trip/snapshot contracts and bounded trace behavior. The integration suite loads source-controlled profile fixtures through real DI, opens actual simulation sessions, sends/decodes requests through the transport, verifies identity/DTC/static signals, virtual clear/readback/reset and independent session state, exercises deterministic malformed/no-response/timeout/cancelled faults, renders the diagnostic route against the actual provider, and checks the nine-project reference graph. Fixtures are never treated as real vehicle definitions. The internal state oracle is exposed only to the integration-test assembly.
The accepted Step-02A baseline was 103 unit plus 37 integration tests (140 total). The Step-03 worker report records the full, expanded counts, warnings, commands and native observations; do not infer acceptance from these earlier runs. Historical Step-02 had 59 unit and 34 integration cases; it predates the Step-02A corrections. See the Step-02 report and Step-02A report for historical evidence.
Step-03 worker verification ran the nine-project Release build with zero warnings/errors, then passed 108 unit and 53 integration cases (161 total, zero failed/skipped). Its native smoke used the actual Windows Client and verified explicit synthetic selection, module probes/identity, DTC and static signals, raw request/reply trace, virtual clear/readback/reset, close, target metadata, profile, home and not-found routes. Exact observations and limitations are recorded in the Step-03 worker report; the run did not cover the subsequently identified integrity findings and Step-03 was not accepted.
Step-03A added actual failing-before/passing-after regressions for missing and duplicate request fields, semantic response validation/trace consistency, and clear acknowledgement versus verified readback. The final sequential Release verification passed 111 unit tests and 64 integration tests (175 total, zero failed/skipped), preserving the original 161 cases plus 14 additional test cases. Exact commands and outcome details are in the Step-03A corrective report. Manual orchestrator acceptance remains pending.
Step-03B reproduced the probe-only identity-loss defect before the fix through the real Simulation transport: the regression expected a positive probe but observed a negative discovery outcome. After the correction, the focused protocol/UI integration selection passed 35 cases. The complete nine-project Release build passed with zero warnings and errors, and the complete suite passed 111 unit plus 72 integration tests (183 total, zero failed/skipped), preserving all 175 Step-03A cases. Exact commands and AC mapping are recorded in the Step-03B corrective report.
The native Windows Client was launched and the operational baseline was
exercised in its own WebView: explicit example import/profile/revision/provider/
Simulation selection, session open, discovery with expected/probe/identity
counts, configured transmission no-response, engine DTC/static-signal reads,
verified clear with fresh empty readback, raw/decoded trace, reset with initial
DTC restoration, close, and /execution-targets, /vehicle-profiles, /,
and not-found routes. Exact observations and limitations are in the
Step-03B corrective report. Native interaction
used a session-local WebView debug port on the worker-launched Client; partial
identity remains covered by real-DI rendered tests because the shipped native
configuration has no fault selector for that scenario.
Step-04 fixed-step dynamics verification
The Step-04 Release regression ran sequentially against the full solution:
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
The native Windows-targeted build covered all nine solution projects with zero warnings/errors. The complete test command passed 115 unit and 75 integration tests (190 total, zero failed/skipped), preserving the Step-03B 183-test baseline. The unit numerical gate executes 3,361 deterministic 0.1-second samples and compares full sampled state across equal runs. The baseline results were: 10.0 s warm idle at 650.000 rpm; acceleration to 20.1473 m/s in 10.3 s with four scheduled shifts; all 3,000 cruise samples inside the configured 45-MPH +/- 1-MPH band and fully coupled; braking to 0.0000 m/s in 5.8 s; 10.0 s return idle; and 0.518387 kg modeled total fuel. These are synthetic model outputs, not measured vehicle performance or manufacturer predictions.
The actual Windows Client was launched with WebView2 local DevTools enabled for
the native smoke. /simulation required explicit selection of profile
autoforge.synthetic.test-truck revision 1, provider
autoforge.simulation.dynamics, and a configuration with fingerprint
sha256:v1:e8991ae139b54959ec53a4fe64b08dc9bfc03feb533496cf741f2c9f3a2342da.
Export/import preserved that fingerprint. A stopped open session returned 17
protocol-v2 dynamic telemetry values at step 4 / 0.4 model seconds after explicit
start/pause/step controls. The accelerated full scenario completed at step
3,361 / 336.1 model seconds with 17 telemetry values and four shifts. Invalid
{} import visibly reported the missing required formatVersion; exact-config
reset opened a new session at step 0 with the same fingerprint, and close
released it.
The native /diagnostics regression separately selected the original
autoforge.simulation.synthetic provider, discovered two positive probes out
of three expected endpoints (the transmission remained configured no-response),
and read the original engine DTC plus static 850-rpm and 12.6-V signals through
protocol v1 with trace records. The session was closed. Native route smoke
covered /execution-targets (both providers remain metadata), /vehicle-profiles,
/, and an unmatched not-found route. Numerical fidelity and reproducibility
are established by headless tests, not by visual telemetry.
Native synthetic diagnostics smoke
Launch the actual Windows Client and visit /diagnostics:
- Confirm the page starts without selecting/importing a profile or opening a session. Click Load synthetic truck example; verify the profile appears as an available revision but remains unselected.
- Explicitly select
autoforge.synthetic.test-truck, revision1, providerautoforge.simulation.synthetic, and kindSimulation. Click Open simulation session and confirm the visible session/profile/provider/ configuration identity. The session opens in process only. - Click Probe virtual modules. Engine/body respond; the configured transmission endpoint visibly reports no response and is not reported as an actual responder. Inspect the identity and declared implemented services.
- Read the engine's DTCs and static signals. Values are synthetic static snapshots with source, unit, quality and logical tick. Expand the bounded trace to inspect actual request/response JSON and correlation values.
- Clear the supported engine virtual DTCs, confirm the fresh readback is empty, and confirm the UI explicitly states that no physical write occurred. Other module/session state is isolated.
- Exercise a visible deterministic failure (for example the configured transmission no-response), then reset to the initial synthetic state and close the session. Closing releases that session's trace and virtual state.
- Separately visit
/execution-targets,/vehicle-profiles,/, and an unmatched route. Confirm metadata selection remains separate from an operational session and the not-found/navigation behavior remains.
The Step-03A report records actual native baseline smoke separately from headless rendered fault tests. The native Client revalidated explicit profile/provider selection, successful clear with fresh empty readback, trace/raw frames, visible no-response, reset/initial-state restoration, close and existing routes. A deliberately false clear acknowledgement was injected only in the rendered integration composition; the production Client has no UI fault selector, so this is not native fault-injection evidence.
Profile-schema and safety boundaries
See the schema-v1 guide for field, identity, unknown-value, capability, provenance and strict JSON rules. Important invariants:
- Every v1 field is required; unknown optional facts are explicit JSON
null. Unknown fields and duplicate/case-ambiguous properties are rejected. - Catalog selection requires exact
(profileIdentifier, revision). Duplicate imports do not replace entries, and failed parsing cannot partially register. publishedAt/retrievedAtaccept null or completeYYYY-MM-DDTHH:mm:ss[.fraction](Z|+HH:mm|-HH:mm)timestamps only. The exact fractional and offset limits and no-default policy are in the schema guide.- A null optional module identity in evidence is an absent constraint. Any supplied identity must match a known module value; an unknown target or mismatch is rejected without identity inference.
- Imported profiles and capability/provenance statements are immutable metadata, not connection, compatibility, a working service or authorization.
- Data remains in memory for the process only. JSON import/export does not write files or timestamps implicitly.
- Static synthetic diagnostics use the protocol v1 guide and simulation definitions; dynamic output uses the separate documented protocol-v2 provider. Neither is a real vehicle adapter, telemetry capture, replay provider, calibration/firmware editor or hardware write path.
Step-04A corrective verification
Step-04A corrects typed import errors for unavailable profile/revision/module or conflicting calibration references, enforces the supported coupled RPM/redline envelope, and makes progress, terminal failure and asynchronous runner ownership explicit. It adds seven unit and five integration cases over the 190-case Step-04 baseline. The final sequential commands were:
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
The nine-project Windows Release build succeeded with zero warnings and zero
errors. The full test command passed 122 unit and 80 integration tests (202
total; zero failed/skipped). The warm baseline remains reproducible at 3,361
samples / 336.1 virtual seconds; 10.0 s warm idle at 650 rpm, 10.3 s acceleration
to 20.1473 m/s with four shifts, all 3,000 cruise samples in the original
45-MPH +/- 1-MPH band while coupled, braking to 0.0000 m/s in 5.8 s, 10.0 s
return idle, and 0.518387 kg modeled fuel. The added independent constant-torque
force/mass equation and speed-step equation checks use a 1e-10 acceleration
tolerance; independent locked RPM checks use 1e-8 rpm.
Controlled-pacer unit tests exercised active pause/freeze, resume, stop, reset,
restart, cancellation and disposal without wall-timer polling. Equivalent full
scenario samples were identical at 0.25x and 1000x; only requested pacing delay
changed. Rendered integration tests covered typed/atomic profile, revision and
module import failures; a persistent 0.1-second deadline failure and negative
DYNAMICS_RUN_FAULTED response; UI run reentrancy; and stale-run suppression
across reset, close, reopen and delayed open.
Headless numerical/integration coverage also accepts a finite but extreme
torque/gear vector that overflows modeled power during launch. The engine
rolls back to its last finite state/sample, marks the lifecycle Faulted, and the
real v2 session returns a negative DYNAMICS_RUN_FAULTED response rather than
encoding poisoned values.
The rebuilt Windows Client was launched at
src/AutoForge.Client/bin/Release/net10.0-windows10.0.26100.0/win-x64/AutoForge.Client.exe
and operated through its local WebView2 session. Import of unknown profile,
revision and module references showed recoverable error notices without
changing the selected valid configuration. The short-deadline run visibly ended
Faulted at step 101 / 10.1 model seconds; the failure remained visible after a
dynamic diagnostic read and previously good telemetry rows were cleared. A
valid baseline run completed at step 3,361 / 336.1 model seconds. The active
runner was then paused and held at step 1 while waiting, resumed, stopped,
explicitly stepped, reset to a new step-0 session, read 17 SYNTHETIC_DYNAMIC
values at step 0, exported/re-imported the configuration, and closed. The
/diagnostics, /vehicle-profiles, /execution-targets, /, and unmatched
not-found routes loaded. The launched Client and its local DevTools listener
were closed and verified absent afterward.
The Step-04 worker report remains historical; the corrective evidence is in the Step-04A report. Step-04/04A/04B are accepted. All model and telemetry values remain synthetic.
Step-04B owner-drain corrective verification
Start and resume now reject before changing lifecycle state when a previous
advancement owner is still cleaning up after pause, stop or reset. The real
simulation page reports that rejection as an error rather than a successful
start/resume. Controlled barrier tests reproduced the prior defect: while the
cancelled owner was held in cleanup, Pause-to-Resume changed Paused to
Running, Stop-to-Start changed Stopped to Running, and Reset-to-Start
changed Stopped at step 0 to Running. After the guard, all three complete
status snapshots and sample counts remain unchanged on rejection; releasing
cleanup then permits exactly one retry and one new fixed step.
The final sequential Release build covered all nine solution projects and succeeded with zero warnings and zero errors. The full solution test command passed 126 unit and 81 integration tests (207 total; zero failed/skipped), preserving all 202 Step-04A cases. Focused owner-drain regressions passed 4 unit and 2 integration tests. See the Step-04B corrective report for exact commands and detailed contract evidence.
The actual native Windows Client smoke exercised start, active pause/resume,
stop/restart, reset, protocol-v2 telemetry read and close. It confirmed stable
paused/stopped steps, a reset session at step 0, SYNTHETIC_DYNAMIC telemetry,
and release of the closed session. This manual UI smoke does not claim to force
the cleanup interleaving; that exact race is established by the controlled
headless tests. The Client and its task-local WebView2 debug listener/profile
were stopped and cleaned up. Step-04/04A/04B are accepted; the prior numerical
thresholds and synthetic-only scope are unchanged.
Step-05A live dashboard corrective verification
The corrected dashboard is shared by the actual /diagnostics static-v1 and
/simulation dynamics-v2 workflows. Focused headless checks passed:
dotnet test .\src\tests\AutoForge.UnitTests\AutoForge.UnitTests.csproj --configuration Release --no-restore --filter FullyQualifiedName~LiveDashboardGaugeRenderingTests— 7 passed, 0 failed, 0 skipped.dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~LiveDashboard|FullyQualifiedName~RealApplicationAndRenderedRoute"— 10 passed, 0 failed, 0 skipped. The selection includes controlled feed, actual static/dynamic provider, rendered panel, lifecycle and startup regression cases.dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter FullyQualifiedName~RealApplicationAndRenderedRoute_RunAndReadDynamicTelemetryWithoutOracle— 1 passed, 0 failed, 0 skipped; the real/simulationroute renders the shared dashboard panel for an open dynamics session.
The required sequential full commands were then run:
dotnet build .\src\AutoForge.slnx --configuration Release --no-restore
dotnet test .\src\AutoForge.slnx --configuration Release --no-build
The build succeeded for all nine projects, including the native Windows Client, with 0 warnings and 0 errors. The MAUI XAML source-generation notice was informational. The complete suites passed 133 unit and 91 integration tests (224 total, 0 failed, 0 skipped), preserving the 207-case baseline and adding 17 dashboard-focused cases.
The actual Windows Client smoke used .NET SDK 10.0.402/runtime 10.0.13, MAUI
workload 10.0.403 / maui-windows manifest 10.0.110, Windows SDK target
10.0.26100.0 and WebView2 Runtime 156.0.4314.50. On /diagnostics, the worker
explicitly imported and selected the synthetic truck/profile/provider, opened
the static session, and started monitoring before selecting verified bindings.
The native editor visibly rejected an invalid range and an rpm signal bound
to km/h without adding a gauge or stopping the feed. A numeric gauge rendered
850 rpm; a bar first rendered 850 rpm below its configured range at 0% geometry,
then after editing to 0..1000 rendered 85%. Removing it and hiding the remaining
gauge did not stop polling. Stop/restart succeeded on the same session. Reset
created a new session with a stopped empty dashboard and no prior gauge values;
a fresh feed started on the replacement session, and close removed the panel.
On /simulation, the actual v2 session was paused at step 1 / 0.1 model seconds.
The dashboard rendered SYNTHETIC_DYNAMIC engine speed and vehicle speed with
logical request ticks, model step/time, configuration fingerprint and run ID.
After an explicit 200-step command, the readings updated to step 201 /
20.1 seconds (2,795 rpm and 19.7 m/s). Two later polls kept the paused model at
step 201. Reset opened a new step-0 session/run with an empty stopped dashboard;
the first new run sample displayed dynamics-run-000002, not the prior run.
Close released the panel. The existing execution-target, profile, home and
not-found routes loaded. Both temporary Client/WebView2 processes and their
isolated user-data profiles were stopped/removed; loopback debug listeners were
verified closed. See the Step-05A corrective report
for the named controlled fault/lifecycle evidence and full acceptance mapping.
After the final source-path cleanup, the rebuilt Client was launched again;
actual static-v1 and dynamics-v2 sessions each reached dashboard cycle 1 and
closed cleanly with the panel removed.
Step-05B range and boundary verification
The Uncertain projection now computes its range status independently of source
quality. Before the fix, the real-provider regression failed on the actual
Uncertain -10 rpm sample: expected OutOfRangeLow, actual null. After the
fix, the focused unit suite passed 8 cases and the focused integration selection
passed 3 cases, including real-provider Uncertain -10/1100 readings rendered
through both numeric and bar gauges, Uncertain values at both exact bounds,
atomic invalid-definition vectors, and controlled Stop-drain cleanup.
The full post-fix Release build succeeded for all nine projects with 0 warnings and 0 errors; the MAUI XAML source-generation notice was informational. The full Release test suite passed 134 unit and 91 integration tests (225 total, 0 failed, 0 skipped).
On the exact rebuilt native Client and an isolated WebView2 profile, the static
editor configured a horizontal bar from the real SYNTHETIC_STATIC engine
signal and displayed 850 rpm. The dynamics editor configured a numeric gauge
from the real SYNTHETIC_DYNAMIC engine signal and displayed 260 rpm with
logical tick, model step/time, configuration fingerprint and run identity; the
model was paused at step 1 / 0.1 seconds. Both sessions closed with their
dashboards, the exact test processes and port 9351 were verified stopped, and
the isolated test profile was removed. The older shared WebView2 profile was
left untouched. These native observations confirm the dashboard baseline; the
Uncertain and malformed-input cases are established by controlled tests, not
claimed as native UI injection.
Step-05 with Step-05A and Step-05B was accepted by the orchestrator on 2026-10-29. These historical worker results remain distinct from that manual acceptance.
Step-06 display-unit verification
The shared shell defaults to Imperial (US) / Road and persists explicit Metric/Imperial (US) and Road/Engineering selections through the native MAUI Preferences adapter. Portable tests inject an isolated store; controlled read, write, corrupt-value and invalid-selection cases exercise the same application service without modifying platform preferences. Pure tests cover the specified forward/inverse conversion vectors, affine temperature bounds, finite/overflow handling, exact pass-through/unknown units and conversion before rounding. Rendered real-provider coverage toggles all speed modes repeatedly on a paused dynamics session and verifies unchanged source snapshots, gauge definitions, trace/request count, configuration export, model state and bar percentage.
Current command outcomes and exact complete suite counts are recorded in the Step-06 worker report. Native persistence and draft-editor observations are reported separately from controlled storage failure/error tests; headless verification does not substitute for the actual Windows Client smoke. This section preserves the original Step-06 worker evidence; the subsequent Step-06A correction and current review status are recorded below. At that time, Step-07 recording had not yet run; replay remains outside Step-07 scope.
The final sequential Release build completed all nine projects, including the Windows Client, with 0 warnings and 0 errors. The full suite passed 178 unit and 92 integration tests (270 total; 0 failed/skipped), preserving the accepted 225-case Step-05B baseline and adding 44 unit plus one integration case. Focused display-unit tests passed 44/44; the focused real static/dynamic/rendered integration selection passed 3/3.
The rebuilt Windows Client was launched with task-local WebView2 debug port 9361 and an isolated temporary WebView profile. Its initial native shell showed the Imperial (US) / Road first-use default before any session; the key had no saved selection. A real static v1 session rendered 850 rpm unchanged after switching the shared selectors. A real dynamics v2 session was paused at step 203 / 20.3 seconds and returned 20.1168 m/s. Its bar displayed 45 mph / 0..90 mph, 66 ft/s / 0..132 ft/s, 72 km/h / 0..144.84096 km/h, and 20 m/s / 0..40.2336 m/s; all modes kept 50% geometry, the exact 20.1168 m/s source reading, and step 203.
The native range editor saved 0..90 mph as canonical 0..40.2336 m/s. An open
10..110 mph draft retained its mph labels and values after the global system
changed to Metric; saving produced source bounds
4.470400000000001..49.174400000000006 m/s and the equivalent Metric/Road
display range. An invalid 200..100 range surfaced an alert and preserved the
prior gauge; an unedited Save retained its exact existing source bounds.
Protocol-v2 telemetry displayed Imperial numeric readings while retaining
source kg/s, N*m, degC and exact source speed alongside them. Exported
configuration remained 2,789 characters, contained the unchanged SI target
20.1168 and no display-unit labels, and kept its fingerprint. Reset opened a
new stopped step-0 session/run with an empty dashboard; close released it.
The native app was closed and reopened: Imperial (US) / Road restored as a
saved choice. Existing diagnostics, execution-target, profile, home and
not-found routes loaded without an error banner. Only the exact temporary
WebView profile was removed; the preference created by this smoke was left at
the sensible Imperial/Road default, and no unrelated preferences were changed.
Step-06A corrective verification
The original Step-06 review found invalid-selection initialization/storage mutation and unavailable/wrong-type readout presentation gaps. Step-06A closes those gaps without changing the approved defaults, mappings, editor policy, model/source data or protocol. Step-06 remains not accepted pending manual review; Step-07 had not yet run at that point. The final Step-07 evidence is recorded below.
Before the fix, an invalid proposal on a fresh service loaded the saved
metric|road selection instead of leaving the untouched default; store reads
were not zero. The presentation regressions observed "null" for a null
numeric measurement, echoed "not a number" for a string-valued m/s signal,
and omitted an unconverted notice for unsupported-unit text. After the fix,
PreferenceService_RejectsInvalidChoiceBeforeInitializingOrReadingStore,
RejectedSelectorEventReconcilesControlAndReadoutAndCanRetry (both selectors),
DiagnosticRoute_RendersNullWrongTypeUnknownAndUnsupportedStaticV1SignalsTruthfully,
and FormatSourceValue_PreservesJsonNullAndBooleanLexicalValues pass as part
of the full suite. Real-provider controlled tests cover converted Uncertain,
Stale, Stopped and failed-display projections; protocol-v2 validation remains
strict.
The final sequential Release build completed all nine solution projects with 0 warnings and 0 errors; the MAUI XAML source-generation notice was informational. The complete suites passed 179 unit and 105 integration tests (284 total; 0 failed, 0 skipped), preserving the 270-case Step-06 baseline and adding 14 corrective cases. Exact final commands:
dotnet build .\src\AutoForge.slnx --configuration Release --no-restoredotnet test .\src\AutoForge.slnx --configuration Release --no-build
The rebuilt Windows Client smoke used the task-isolated WebView2 debug port
9361 and an isolated LOCALAPPDATA/WebView2 profile. First use showed
Imperial (US) / Road. A real static v1 session rendered 850 rpm unchanged. A
real paused v2 session at step 203 / 20.3 seconds retained exact source
20.1168 m/s while native readouts displayed 20.117 m/s, 72.420 km/h, 45.000
mph and 66.000 ft/s across all four selections. A native horizontal bar
displayed 72 km/h from source 20.1168 m/s over 0–144.84096000000002 km/h with
50% geometry. Its open Metric/Road editor draft remained in km/h after the
global selection changed to Imperial (US)/Engineering; closing and reopening
the app restored the task-isolated Metric/Road preference. Both static and
dynamics sessions closed and released their dashboards.
The native smoke did not inject a platform storage failure or malformed v1 values. Those cases are covered by controlled store tests and the real static v1 rendered integration path, respectively. All native preference/profile data was written under the task-owned isolated profile; that exact profile was removed after both Client processes and port 9361 were closed. No unrelated user preference/profile data was changed. See the Step-06A corrective worker report for matrix-level evidence, limitations and preservation review.
Step-07 bounded telemetry recording verification
The final sequential Release build completed all nine solution projects, including the Windows Client, with zero warnings and zero errors. The MAUI XAML source-generation notice was informational. The full suite passed 179 unit and 124 integration tests (303 total; zero failed and zero skipped), preserving the Step-06A baseline of 284 and adding 19 integration regressions. The focused telemetry recording selection passed 19/19, including the cross-scope capture-retention regression. Commands:
dotnet build .\src\AutoForge.slnx --configuration Release --no-restoredotnet test .\src\AutoForge.slnx --configuration Release --no-builddotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --no-restore --filter "FullyQualifiedName~TelemetryRecordingIntegrationTests"
The rebuilt Windows Client was launched with isolated task-owned WebView2
profiles and local DevTools ports. A static v1 session captured seven actual
operations (including positive and no-response discovery, DTC and signal reads),
closed with SourceClosed, saved locally, then was loaded after app restart.
The readback showed autoforge.synthetic-diagnostics v1, endpoint 0x10, raw
request/response payloads, and two decoded source signals (850 rpm and
12.6 V). A dynamics v2 session was paused at step 8 / 0.8 model seconds.
With gauges hidden, two actual read.signals observations captured exact
configuration/run and model step/time context. The panel was unmounted by
navigating Home; the session close stopped the capture as SourceClosed,
and its unsaved snapshot remained available on the dynamics route for explicit
save. After another Client restart, both archives loaded and exposed raw bytes
and decoded signals; the static capture had two signals and the dynamics
capture had five. The displayed Metric/Road selection remained unchanged.
That route-unmount smoke exposed a scoped-workspace lifetime bug; the workspace
was changed to application-wide singleton lifetime and
CaptureWorkspace_IsSharedAcrossHostScopesAndRetainsClosedSourceCapture
regresses it. Native post-fix evidence confirms the capture survives unmount
and source close. The UI also renders protocol versions and endpoint addresses
without Razor interpolation artifacts. Controlled tests, not the native smoke,
cover exact fixed limits, malformed archives, cancellation, collision and
filesystem failures.
The LOCALAPPDATA override isolated neither MAUI's
FileSystem.AppDataDirectory nor display preferences on this Windows
environment. The application initially listed zero archives; the two
task-generated captures were written to its app-local recordings directory,
then those exact IDs were removed after closing the Client. No pre-existing
capture was overwritten or deleted. The WebView2 profiles were task-owned
temporary directories and were removed. Metric/Road preferences were observed
but not changed. See the Step-07 worker report
for frozen-matrix evidence, self-review and preservation details. Worker
completion remains pending manual orchestrator review; no Step-08 work began.
Step-07A corrective recording verification
Step-07 remains historically NOT ACCEPTED; this correction preserves its
303-case baseline and native smoke evidence. Before the fixes, the focused
recording selection ran 23 tests with 17 passing and 6 failing. The failures
reproduced actual boundary defects: an empty TransportOutcome.Response was
rejected before it could be archived; source-accepted case-variant identities
were rejected on readback; a positive signal read with a null snapshot escaped
as NullReferenceException; a stopped capture remained in the session
registration list; an existing file used as the storage root listed as empty;
and an actual panel save collision was followed by catalogue refresh, which
replaced the visible save error with a malformed-archive error. The latter was
also rerun against the real panel event before correction and failed because
the rendered error no longer contained the collision message.
After correction, TelemetryRecordingIntegrationTests passed 26/26. The tests
exercise the actual v1/v2 observation and save/read paths, coherent raw-and-
decoded v2 mutation cases, deterministic stop/error/limit registration release,
invalid and missing storage roots, and the actual panel collision/error/retry
flow. The full Release build completed all nine solution projects, including
the Windows Client, with zero warnings and zero errors; the MAUI XAML source-
generation notice was informational. The full suite passed 179 unit and 131
integration tests (310 total, zero failed and zero skipped). Exact commands:
dotnet test .\src\tests\AutoForge.IntegrationTests\AutoForge.IntegrationTests.csproj --configuration Release --filter "FullyQualifiedName~TelemetryRecordingIntegrationTests"(26/26)dotnet build .\src\AutoForge.slnx --configuration Release --no-restore(nine projects; 0 warnings, 0 errors)dotnet test .\src\AutoForge.slnx --configuration Release --no-build(179 unit + 131 integration; 310 total)
The rebuilt Windows Client was exercised through its local WebView2 DevTools
endpoint. Static v1 captured seven actual operations, then stopped/saved,
closed its source, restarted the app, and loaded/inspected the archive.
Dynamics v2 was paused at model step 7 / 0.7 seconds; with gauges hidden, it
captured four actual read.signals operations, then stopped/saved, closed its
source, restarted, and loaded/inspected the archive. Both readbacks exposed raw
bytes and decoded signals/context; Metric/Road preferences remained unchanged.
Native captures were 034e287ae82e4e14aa4d55e78581cbf1 (static) and
69def5834cf742ce9fa729dd4bea1b16 (dynamics). Those exact task-generated
archive files and temporary WebView2/profile directories were removed after
the Client and DevTools listener were closed.
Native evidence verifies the normal record/stop/save/restart/load/source-close
workflow; it does not claim native filesystem-fault injection. Invalid roots,
save collisions, coherent malformed archives, and error/limit lifetime
cleanup are covered by controlled integration tests. The LOCALAPPDATA
override did not redirect MAUI FileSystem.AppDataDirectory in this
environment. See the Step-07A corrective worker
report for the frozen-matrix mapping,
pre/post-fix outputs, self-review and preservation review. Step-08 remains
blocked pending manual review; no Step-08 work began.